Outcome and serum ion determination up to 11 years after implantation of a cemented metal-on-metal hip prosthesis

نویسندگان

  • Jean-Yves Lazennec
  • Patrick Boyer
  • Joel Poupon
  • Marc-Antoine Rousseau
  • Carine Roy
  • Philippe Ravaud
  • Yves Catonné
چکیده

BACKGROUND AND PURPOSE Little is known about the long-term outcome of cemented metal-on-metal hip arthroplasties. We evaluated a consecutive series of metal-on-metal polyethylene-backed cemented hip arthroplasties implanted in patients under 60 years of age. METHODS 109 patients (134 joint replacements) were followed prospectively for mean 9 (7-11) years. The evaluation included clinical score, radiographic assessment, and blood sampling for ion level determination. RESULTS At the final review, 12 hips had been revised, mainly because of aseptic loosening of the socket. Using revision for aseptic loosening as the endpoint, the survival rate at 9 years was 91% for the cup and 99% for the stem. In addition, 35 hips showed radiolucent lines at the bone-cement interface of the acetabulum and some were associated with osteolysis. The median serum cobalt and chromium levels were relatively constant over time, and were much higher than the detection level throughout the study period. The cobalt level was 1.5 microg/L 1 year after implantation, and 1.44 microg/L 9 years after implantation. INTERPRETATION Revisions for aseptic loosening and radiographic findings in the sockets led us to halt metal-on-metal-backed polyethylene cemented hip arthroplasty procedures. If the rigidity of the cemented socket is a reason for loosening, excessive release of metal ions and particles may be involved. Further investigations are required to confirm this hypothesis and to determine whether subluxation, microseparation, and hypersensitivity also play a role.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Mortality rates at 10 years after metal-on-metal hip resurfacing compared with total hip replacement in England: retrospective cohort analysis of hospital episode statistics

OBJECTIVES To compare 10 year mortality rates among patients undergoing metal-on-metal hip resurfacing and total hip replacement in England. DESIGN Retrospective cohort study. SETTING English hospital episode statistics database linked to mortality records from the Office for National Statistics. POPULATION All adults who underwent primary elective hip replacement for osteoarthritis from ...

متن کامل

The Charnley versus the Spectron hip prosthesis: clinical evaluation of a randomized, prospective study of 2 different hip implants.

Prospective, randomized studies must be performed when new surgical techniques or implants are evaluated. In this study, a new implant system was compared with the Charnley prosthesis, which over the years has been the most used hip implant in Sweden. Between 1985 and 1989, 410 hips were randomized to treatment with a Charnley or a Spectron total hip arthroplasty: 206 Charnley and 204 Spectron ...

متن کامل

No superiority of cemented metal-on- metal over metal-on-polyethylene total hip arthroplasty in a randomized trial at 10-year follow-up

In a randomized controlled trial, 102 cemented Stanmore 28-mm metal-on-metal total hip arthroplasties (THAs) were compared to 98 metal-on-polyethylene THAs in 195 patients. At a mean follow-up of 10 years, 11 patients (11 hips) were lost to followup, 53 patients (55 hips) died, and 6 patients (6 hips) underwent revision. Average age of the surviving patients was 79 years. Harris Hip Scores and ...

متن کامل

Mid-Term Review of ADEPT Metal-On-Metal Hip Prosthesis. Functional, Radiological and Metal Ion Analysis

Background: There is much interest regarding metal-on-metal implants in medical and general media. Much of this has been regarding failure of specific implant systems and metal ion toxicity. We present our early mid-term experience of the ADEPT metal-on-metal system which has both modular and non-modular hip options. Methods: Functional assessment, blood metal ion quantification, and radiograph...

متن کامل

One-year prospective comparative study of three large-diameter metal-on-metal total hip prostheses: serum metal ion levels and clinical outcomes.

INTRODUCTION The good clinical outcomes and low wear obtained with 28-mm metal-on-metal implants for total hip replacement prompted the development of large-diameter heads that more closely replicated the normal hip anatomy, with the goal of improving prosthesis stability. However, the blood release of metal ions due to wear at the bearing surfaces and the high rate of groin pain seen with larg...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 80  شماره 

صفحات  -

تاریخ انتشار 2009