It is shown that accurate values of the rates of enthalpy generation in the electrolysis of light and heavy water can be obtained from measurements in simple, single compartment Dewar type calorimeter cells. This precise evaluation of the rate of enthalpy generation relies on the nonlinear regression fitting of the “black-box” model of the calorimeter to an extensive set of temperature time measurements. The method of data analysis gives a systematic underestimate of the enthalpy output and, in consequence, a slightly negative excess rate of enthalpy generation for an extensive set of blank experiments using both light and heavy water. By contrast, the electrolysis of heavy water at palladium electrodes shows a positive excess rate of enthalpy generation; this rate increases markedly with current density, reaching values of approximately 100 W cm at approximately 1 A cm. It is also shown that prolonged polarization of palladium cathodes in heavy water leads to bursts in the rate of enthalpy generation; the thermal output of the cells exceeds the enthalpy input (or the total energy input) to the cells by factors in excess of 40 during these bursts. The total specific energy output during the bursts as well as the total specific energy output of fully charged electrodes subjected to prolonged polarization (5-50 MJ cm) is 10 10 times larger than the enthalpy of reaction of chemical processes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Electrochemical Loading of Hydrogen and Deuterium Into Palladium and Palladium-Boron Alloys

Excess power production and other anomalous effects have been observed during the electrolysis of heavy water using palladium and palladium-boron alloys as the cathode materials. This study focused on hydrogen and deuterium loading into palladium and palladium-boron alloys. Improved calorimetry provided for the detection of the exothermic heat of absorption of deuterium into palladium and palla...

متن کامل

EXCESS HEAT REPRODUCIBILITY AND EVIDENCE OF ANOMALOUS ELEMENTS AFTER ELECTROLYSIS IN Pd|D2O+H2SO4 ELECTROLYTIC CELLS

Electrolyte temperature is a key factor in excess heat production using Pd|D2O+H2SO4 electrolytic cells. Best results are obtained when the electrolyte temperature is close to the boiling point. Stable excess heat is generated by events on or near the Pd cathode surface. In addition to the stable excess heat, heat bursts are sometimes observed. These occurred most frequently in experiments usin...

متن کامل

Anomalous Heat Generated by Electrolysis Using a Palladium Cathode and Heavy Water

Samples of palladium sheet supplied by IMRA Japan were tested for anomalous energy production using electrolysis in heavy water and a sensitive calorimeter. Several samples were found to produce significant power above that being applied to produce electrolysis. This behavior was found to correlate with certain properties of the palladium metal. In addition, the anomalous heat was shown to orig...

متن کامل

Isoperibolic Calorimetric Measurements of the Fleischmann-Pons Effect

Important advantages exist for selecting a Dewar type isoperibolic calorimeter for measurements of anomalous excess enthalpy produced by the Fleischmann-Pons Effect (FPE). These advantages include a wide dynamic range for both the cell temperature and cell input power, direct visual observations inside the cell during calorimetric experiments, relative low cost, selfpurification of the system, ...

متن کامل

Deuterium Loading Ratio and Excess Heat Generation during Electrolysis of Heavy Water by a Palladium Cathode in a Closed Cell Using a Partially Immersed Fuel Cell Anode

We have developed a novel electrolytic cell pressurized by D2 in which deuterium loading ratio in a palladium cathode can be determined in-situ during the calorimetric measurements of excess heat. A gas diffusion type fuel cell anode is partially immersed in the electrolyte solution to act as a counter electrode, at which electrochemical oxidation of deuterium gas molecules to deuterium ions ta...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1989