BACKGROUND Products containing alcohol are commonly used with intravascular devices at insertion, to remove lipids from occluded intravascular devices used during parenteral nutrition, and increasingly for the prevention and treatment of intravascular device-related bloodstream infection. The effects of alcohol on the integrity of intravascular devices remain unknown. METHODS Two types of widely used commercial peripherally inserted central catheters, one made of polyetherurethane and one made of silicone, were exposed to a 70% ethanol lock solution for up to 10 weeks. Mechanical testing was performed to identify force-at-break, stress, strain, modulus of elasticity, modulus of toughness, and wall area of ethanol-exposed and control catheters. RESULTS No significant differences between exposed and unexposed catheters were identified for any of the mechanical parameters tested except for a marginal reduction in the modulus of elasticity for both polyetherurethane and silicone catheters and minor increases in the wall area of polyetherurethane catheters. CONCLUSIONS These data indicate that exposure to a 70% ethanol lock solution does not appreciably alter the integrity of selected commercial polyetherurethane and silicone catheters. Given the greatly expanded use of alcoholic solutions with intravascular devices of all types, we believe that manufacturers would be well advised to subject their catheters and other intravascular devices to formal testing of the type employed in this study.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Atypical Gitelman syndrome with L623P mutation of the thiazide-sensitive Na-Cl cotransporter gene exhibiting lack of hypocalciuria and increased proximal tubule salt reabsorption.

prevent recurrent central line sepsis. J Infect 2004; 49: 20–22 5. Schwab SJ, Weiss MA, Rushton F et al.Multicenter clinical trial results with the LifeSite hemodialysis access system. Kidney Int 2002; 62: 1026–1033 6. Sissons CH, Wong L, Cutress TW. Inhibition by ethanol of the growth of biofilm and dispersed microcosm dental plaques. Arch Oral Biol 1996; 41: 27–34 7. Laird J, Soutar R, Butche...

متن کامل

Adverse effects associated with ethanol catheter lock solutions: a systematic review.

BACKGROUND Antimicrobial lock therapy has been widely utilized internationally for the prevention and management of intravascular catheter-related bloodstream infections. One of the agents commonly utilized for lock therapy is ethanol. However, a systematic review of adverse events associated with ethanol locks has not been published. METHODS PubMed was searched to collect articles published ...

متن کامل

Biomechanical Evaluation and Comparison of the Artificial and Natural Skin Properties Using Finite Element Method

Introduction: The self-repair process cannot occur in the skin lesions, therefore, skin replacements are used due to the formation of a scar, which resulted in the complete loss of skin. Artificial skin should have the same specifications as the natural skin. The finite element methods were used in this study to evaluate the biomechanichal properties of natural and artificial skins. Materials ...

متن کامل

Effect of non-acoustic properties on the sound absorption of polyurethane foams

In this paper the influence of non-acoustic properties on the sound absorption coefficient of polyurethane foams as a porous medium is investigated. Biot’s equations with transfer matrix method, as the solution approach are employed to evaluate the sound absorption coefficient of selected polyurethane foams. The major issue is the dependency of non-acoustic properties on each other which makes ...

متن کامل

مروری بر فرمولاسیون بازدارنده‌‌های احتراق بر پایه پلی‌یورتان در پیشرانه‌های جامد دو پایه(علمی-ترویجی)

Insulation of solid propellant to controlling and limiting the burning surface and also to avoid of heat transfer to the solid rocket body is done. This type of coating is defined as inhibitors of combustion. Unsaturated polyesters such as polyurethane are used for good chemical compatibility between double base propellant and inhibitor. In this article, the effect of aromatic groups and the ef...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Infection control and hospital epidemiology

دوره 26 8  شماره 

صفحات  -

تاریخ انتشار 2005