چکیده

Context Daily variations in bladder size and position can negatively impact the ability to accurately deliver radiation. Aims We attempted to quantify how bladder volumes and positions change over the course of radiotherapy for muscle invasive bladder cancer and the planning target volume (PTV) margins required to account for such changes. Methods and material Cone-beam computed tomography (CT) images of 28 patients during their first, second, and third fractions and weekly thereafter were acquired. Bladders were contoured and the volume, centre of mass, and the maximal positions were recorded and compared to the planning CT scan. Statistical analysis Bladder parameters were analysed using regression analysis examining for time trends and correlation to the patient, tumour, or treatment-related factors. Results There was great variability in the mean bladder volumes during the radiotherapy courses (154.17 +/- 129.38 cm3). There were no statistically significant trends for volume changes. Deviations in bladder positions were seen but were small in magnitude. No patient factors were identified which could help predict bladder changes clinically. Bladder variability resulted in a high percentage of fractions (39.6%) in which part of the bladder was outside the PTV. Calculated PTV margins (for 90% of the population to receive 95% of the prescription dose) were 1.48 cm right, 1.15 cm left, 2.13 cm posterior, 1.52 cm anterior, 2.23 cm superior, and 0.52 cm inferior. Conclusions Because of random bladder changes, a significant number of fractions were treated in which the clinical target volume (CTV) fell outside of the PTV. Methods to minimize the amount of CTV that is missed on a fraction to fraction basis should be explored.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The impact of benign prostatic hyperplasia on bladder volume in radiotherapy of prostate cancer

Background: Benign prostatic hyperplasia (BPH) is a common disease among older men and many patients with prostate cancer (PC) also have BPH. External beam radiation therapy (EBRT) is one of the important treatments for PC, nevertheless, few studies have analyzed the effect of BPH on EBRT. We tried to know the risk of bladder toxicity by analyzing the bladder volume variability in patients with...

متن کامل

The effects of volumetric changes on radiation doses of the rectum and bladder during radiotherapy in patients with prostate cancer

Background: In prostate radiotherapy, changes in the volume of the bladder and rectum can influence dose delivery. In this study, cone-beam computerised tomography (CBCT) imaging was used to assess volumetric, and corresponding radiation dosimetric changes, for the bladder and rectum in patients with prostate cancer treated using VMAT. Materials and Methods: Treatment planning computed tomograp...

متن کامل

The Impact of Residual Geometric Inaccuracies on Normal Organ Doses in Image Guided-Radiation Therapy of Prostate Cancer Using On-Board Kilovoltage Cone-Beam Computed Tomography

Introduction: The aim of this retrospective study was to evaluate the variations in delivered dose to the bladder, rectum, and femoral heads of prostate cancer patients during a course of treatment by image-guided radiation therapy (IGRT). Materials and Methods: Overall, 15 patients with prostate cancer were selected and. Each week, for each patient five consecutive cone beam computed tomograph...

متن کامل

Analysis of Hip Joint Dose in Prostate Cancer Radiation Therapy: A Dosimetric Comparison of Treatment Plans

Background and purpose: Radiation therapy as a part of cancer treatment is used in almost 50-60% of involved cases. In prostate cancer radiation therapy, a large volume of pelvis is irradiated, so, it is necessary to preserve sensitive organs around the treatment area, especially rectum and bladder. In this study, some dosimetric parameters such as minimum dose (Dmin), maximum dose (Dmax), mean...

متن کامل

Comparison of Radiobiological Models for Radiation Therapy Plans of Prostate Cancer: Three-dimensional Conformal versus Intensity Modulated Radiation Therapy

Purpose: In the current study, using different radiobiological models, tumor control probability (TCP) and normal tissue complication probability (NTCP) of radiotherapy plans were calculated for three-dimensional conformal radiation therapy (3D-CRT) and intensity modulated radiation therapy (IMRT) of prostate cancer.Methods and Materials: 10 prostate plans were randomly selected among patients ...

متن کامل

ارزیابی مقایسه‌ای توزیع دوز مثانه و دوز دریافتی بافت‌های در معرض خطر در انرژی‌های 6 و 15 مگاولت فوتونی در دو روش سه و چهار میدان در پرتودرمانی خارجی سرطان مثانه

Background & Aims: The main aim of this study was to evaluate the effect of the photon energies (6 and 15 MV) and the number of radiation fields (3 fields and 4 fields) on tumor dose distribution and dose received by organs at risk in radiation therapy of bladder cancer. Materials & Methods: In this study, CT images of 12 patients with bladder cancer were used. And 8 different radiation treatme...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2017