How should airways resistance be measured in young children: mask or mouthpiece?
نویسندگان
چکیده
The reproducibility and acceptability of airways resistance measurements using the interrupter technique (MicroRint) obtained using a mouthpiece were compared with those using a face mask. Fifty children aged 4-7 yrs performed four sets of six Rint measurements; two using a mouthpiece and two using a face mask with integral mouthpiece. Complete data were obtained from 45 (90%) children using the mouthpiece and 43 (86%) children using the mask. The two methods were equally repeatable with comparable intraclass correlation coefficients (ICC) and coefficients of variation. Mean Rint values obtained using the mouthpiece were significantly lower than those using the face mask ((mean+/-SD) mouthpiece=0.81+/-0.18 kPa x L(-1) x s, mask=0.88+/-0.24 kPa x L(-1) x s p=0.0002). Although the mean paired differences between the two methods were small (0.07 kPa x L(-1) x s), the ICC and limits of agreement confirmed that the two methods could not be used interchangeably. Sixty-seven per cent of children preferred the face mask but this was more time-consuming (p = 0.03). Children did not produce more repeatable results using their preferred method, nor did they improve with practice. Repeatable airway resistance measurements using the interrupter technique can be obtained from young children using either a mouthpiece or a face mask, but there are significant clinical and statistical differences between the results obtained.
منابع مشابه
Lung deposition of aerosol--a comparison of different spacers.
AIMS To investigate (1) aerosol lung deposition obtained from two small volume conventional spacers (Babyhaler and Aerochamber) and a home made spacer (modified 500 ml plastic cold drink bottle); (2) the effect of using a face mask or mouthpiece; and (3) the relation between age and pulmonary deposition. METHODS Lung deposition of aerosolised technetium-99m DTPA inhaled via spacer was measure...
متن کاملDrug delivery.
What we know: In preschool children, small-volume spacers perform better than large-volume spacers. Detergent is the best antistatic agent for spacers, increasing lung delivery two- to threefold, but it must not be rinsed off. A mouthpiece should be used in children aged 2-3 years or older, as lung delivery is two- to threefold higher for oral inhalation than nasal inhalation (ie, by mask). Inh...
متن کاملInfant aerosol holding chamber face masks: not all are born equal!
Face masks are used for many respiratory care applications, such as anesthesia, resuscitation, and aerosol therapy. In pediatric practice, particularly with infants and toddlers, aerosol therapy is usually administered by means of a small-volume nebulizer and face mask. Because of their convenience, speed of administration, versatility, dose accuracy, reproducibility, near-optimal mass median a...
متن کاملReview of optimal characteristics of face-masks for valved-holding chambers (VHCs).
Inhaled drugs are frequently given to infants and young children with a pressurized metered-dose inhaler (pMDI) attached to a valved-holding chamber (VHC) with face mask. In young children and infants who cannot breathe through a mouthpiece, the face mask serves as the interface between the patient and the VHC. Although the mask interface is one of the most important factors determining the dos...
متن کاملVital capacity and tidal volume preoxygenation with a mouthpiece.
We have measured oxygen wash-in in 20 volunteers undergoing preoxygenation with a face mask, mouthpiece alone and a mouthpiece with a noseclip, in a crossover study. Tidal volume breathing and maximal deep breath techniques were studied with each type of equipment. When tidal volume breathing was used, the face mask and mouthpiece with noseclip were comparable, but the mouthpiece alone achieved...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The European respiratory journal
دوره 17 6 شماره
صفحات -
تاریخ انتشار 2001