Computational postprocessing quantification of small bowel motility using magnetic resonance images in clinical practice: An initial experience.
نویسندگان
چکیده
PURPOSE To study the feasibility and to gauge the potential clinical impact of quantifying small bowel motility using magnetic resonance imaging (MRI) in a larger population with a spectra of gastrointestinal conditions with impaired small bowel motility. MATERIALS AND METHODS Data were gathered retrospectively from a cohort of 127 patients undergoing MR enterography (1.5 Tesla) in 2011. Cine motility sequences were processed with validated motility analysis software and a parametric motility map was generated. Regions of interests were drawn in the jejunum, ileum, and terminal ileum, and Jacobian standard deviation mean motility index' score (MIS) was calculated. Patients were divided into Crohn's disease (CD), ulcerative colitis, irritable bowel syndrome, and healthy subjects. RESULTS In CD, terminal ileum motility was lower in comparison to healthy subjects (mean difference: -0.1052 arbitrary units, 95% confidence interval: -0.1981--0.0122, P = 0.018). Subgrouping of CD showed that the difference was recognized in patients with disease limited to the small bowel (mean difference: -0.1440 arbitrary units, 95% confidence interval: -0.2491--0.0389, P = 0.002). Visible dysmotility of terminal ileum on MRI reflected a reduced MIS compared with normal motility (0.22 ± 0.09 and 0.33 ± 0.15 arbitrary units, respectively, P = 0.043). Motility correlated negatively between ileum and age (P = 0.021), and between terminal ileum and C-reactive protein in ulcerative colitis (P = 0.031). CONCLUSION Motility quantitation revealed a significant difference in motility of terminal ileum in patients with small bowel CD compared with healthy subjects, concording with visible dysmotility and inflammatory changes. J. Magn. Reson. Imaging 2016;44:277-287.
منابع مشابه
Designing and Fabrication of a New Radiofrequency Planar microcoil for mini-Nuclear Magnetic Resonance
Introduction Radiofrequency planar microcoils are used to increase the resolution of magnetic resonance images of small samples. In this study, we aimed to design and fabricate a spiral planar microcoil constructed on a double-sided printed circuit board (PCB). It has four rings with an internal diameter of 241 microns tuned and matched at 63.8 MHz. Materials and Methods To achieve the maximum ...
متن کاملMagnetic resonance imaging of feline eye
The purpose of this study was to investigate magnetic resonance imaging (MRI) of the normal feline eyeand optic nerves using T1-weighted and T2-weighted images. A total of 6 healthy female domestic short haircats age 2-2.5 years and weighing 3.2 ± 0.4 kg were selected. Magnetic resonance imaging data werecollected using GEMSOW (Philips) at a magnetic field strength of 1.5 T. Dorsal, sagittal, a...
متن کاملEffects of a 5-HT(3) antagonist, ondansetron, on fasting and postprandial small bowel water content assessed by magnetic resonance imaging.
BACKGROUND 5-HT(3) antagonists have been shown to be effective in relieving the symptoms of irritable bowel syndrome with diarrhoea (IBS-D). Using a recently validated magnetic resonance imaging (MRI) method, we have demonstrated reduced fasting small bowel water content (SBWC) in IBS-D associated with accelerated small bowel transit. We hypothesized that slowing of transit with ondansetron wou...
متن کاملAnalysis of liver viscosity behavior as a function of multifrequency magnetic resonance elastography (MMRE) postprocessing.
PURPOSE To analyze the relevance of the viscosity measurement as a liver diagnostic marker. MATERIALS AND METHODS To determine the level of fibrosis, a Fibroscan test was performed on 40 subjects (10 healthy volunteers and 30 patients). Subsequently, multifrequency magnetic resonance elastography (MMRE) tests were made with a pneumatic driver at 60, 70, and 80 Hz. Phase images were analyzed w...
متن کاملFabrication of New 3D Phantom for Measuring Geometric Distortion in Magnetic Resonance Imaging System
Introduction: Geometric distortion is a major shortcoming of magnetic resonance imaging (MRI), which has an important influence on the accuracy of volumetric measurements, an important parameter in neurology and oncology. Our goal is to design and construct a new three- dimensional phantom using a 3D printer in order to measure geometric distortion and its reproducibility in...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of magnetic resonance imaging : JMRI
دوره 44 2 شماره
صفحات -
تاریخ انتشار 2016