Trabecular meshwork bypass tube shunt: initial case series.

نویسندگان

  • D Spiegel
  • K Kobuch
چکیده

AIMS This study describes a prospective consecutive case series of the initial six eyes of five patients undergoing implantation of the trabecular bypass tube shunt. METHODS A prospective consecutive case series. The initial six eyes of five patients with uncontrolled open angle glaucoma who had never previously undergone ocular surgery. Implantation of the trabecular bypass tube shunt measuring 150 micro m outer diameter and 50 micro m inner diameter was performed with the distal end placed in Schlemm's canal and the proximal end in the anterior chamber. The main outcome measures were visual acuity, intraocular pressure, glaucoma medication use. RESULTS The tube was successfully implanted in five of six eyes. In four eyes longer term follow up of 5-9 months showed no loss of visual acuity with decreased intraocular pressure from preoperative levels (mean 23.4-16.5 mm Hg) and reduced requirement of glaucoma medications (mean 3-0.5). In a subset of two eyes, there was no measured increase in aqueous flare or reduction of endothelial cell count. In one eye the tube was explanted because of presumed misplacement by excessive bleeding during surgery. Two eyes showed a diffuse bleb. CONCLUSIONS This study reports the initial experience with a novel approach to surgical glaucoma therapy. This very small tube allows a direct communication to be established between the anterior chamber and Schlemm's canal, effecting a trabecular bypass. In this small number of eyes this procedure reduced intraocular pressure and the need for glaucoma medications without appreciable side effects.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optical Coherence Tomography Observation of Gonio Structures during Microhook Ab Interno Trabeculotomy

INTRODUCTION Intraoperative observation of ocular structures using microscope-integrated optical coherence tomography (iOCT) has been adopted recently. I report my initial feasibility assessment of iOCT for the incised trabecular meshwork observation during microhook ab interno trabeculotomy. CASE SERIES Both the nasal and temporal sides or either side of the trabecular meshwork/inner wall of...

متن کامل

Microhook ab interno trabeculotomy, a novel minimally invasive glaucoma surgery

Trabeculotomy (LOT) is performed to reduce the intraocular pressure in patients with glaucoma, both in children and adults. It relieves the resistance to aqueous flow by cleaving the trabecular meshwork and the inner walls of Schlemm's canal. Microhook ab interno LOT (µLOT), a novel minimally invasive glaucoma surgery, incises trabecular meshwork using small hooks that are inserted through corn...

متن کامل

Self-complementary AAV virus (scAAV) safe and long-term gene transfer in the trabecular meshwork of living rats and monkeys.

PURPOSE AAV vectors produce stable transgene expression and elicit low immune response in many tissues. AAVs have been the vectors of choice for gene therapy for the eye, in particular the retina. scAAVs are modified AAVs that bypass the required second-strand DNA synthesis to achieve transcription of the transgene. The goal was to investigate the ability of AAV vectors to induce long-term, saf...

متن کامل

Confocal microscopic examination of trabecular meshwork removed during ab externo trabeculectomy.

AIMS The aim of the ab externo trabeculectomy (AET) is to remove the external portion of the trabecular meshwork (ETM) responsible for the main aqueous outflow resistance in glaucoma patients, with no opening of the anterior chamber. ETM characteristics were evaluated with a confocal microscope. METHODS A prospective comparative observational case series was performed in 60 consecutive medica...

متن کامل

Flow simulation of the intracoronary shunt tube for off-pump coronary artery bypass.

INTRODUCTION To simulate blood flow provided by the intracoronary shunt tube, and to clarify whether this method is actually suitable for Off-pump coronary artery bypass (OPCAB), we investigated the efficacy of the intracoronary shunt tube in a theoretical model on the basis of fluid dynamics. METHODS Fluid dynamics analysis was performed to simulate flow decrease after attachment on an intra...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The British journal of ophthalmology

دوره 86 11  شماره 

صفحات  -

تاریخ انتشار 2002