Improving Fat Suppression in Radial Coronary Mra Using a Weighted Golden Ratio Acquisition

نویسندگان

  • C. Prieto
  • R. Botnar
  • T. Schaeffter
چکیده

INTRODUCTION: Coronary MR angiography benefits from the favorable motion properties of radial k-space sampling [1-2], which allow reducing scan time by use of longer cardiac acquisition windows [3]. However, recovery of epicardial fat signal during the prolonged data acquisition window may impair image quality as radial trajectories repeatedly sample the center of k-space. Moreover, the effectiveness of the fat suppression may depend on the subject specific epicardial fat distribution. Here we investigate the use of a k-space filtered golden radial acquisition [4] to overcome this problem. The filtering is used to consider the k-space central data only for those radial projections with sufficient fat suppression. The golden angle approach has been chosen as it allows retrospective subject specific filter adaptation for optimal fat suppression.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Self-Gated Free Breathing 3D Coronary Cine Imaging With Enhanced Artery Contrast by Exploiting the Simultaneously obtained Water and Fat Visualization

INTRODUCTION In this work, a respiratory and cardiac self-gated free-breathing 3D cine SSFP imaging technique is proposed utilizing multiple echo acquisitions to separate water and fat for optimal visualization of the coronary arteries. Multi-echo hybrid radial sampling has been shown to have a high data acquisition efficiency and a high robustness to motion. By frequently acquiring the k-space...

متن کامل

Improved coronary artery definition with T2-weighted, free-breathing, three-dimensional coronary MRA.

BACKGROUND Three-dimensional (3D) navigator-gated and prospectively corrected free-breathing coronary magnetic resonance angiography (MRA) allows for submillimeter image resolution but suffers from poor contrast between coronary blood and myocardium. Data collected over >100 ms/heart beat are also susceptible to bulk cardiac and respiratory motion. To address these problems, we examined the eff...

متن کامل

3T Coronary MRA using 3D Multi-interleaved Multi-echo Acquisition and VARPRO Fat-water Separation

Introduction: Coronary MR Angiography is a valuable tool for non-invasive assessment of coronary arteries. Presently, contrastenhanced, fat-saturated, ECG-triggered and navigator-gated 3D spoiled gradient-echo sequence is employed for whole-heart Coronary MRA at 3T. However, large static field variations at 3T frequently result in non-uniform fat-suppression over the field-of-view (FOV), obscur...

متن کامل

Contarst-enhanced whole-heart coronary MRA in 5 minutes using radial EPI

INTRODUCTION: Whole-heart coronary MRA is challenging due to the long data acquisition time on the order of 8-12 minutes. Interleaved EPI using Cartesian kspace sampling has been reported for reducing the scan time of whole-heart coronary MRA [1]; however, this method suffers from an increased sensitivity to motion artifacts [2]. The purpose of this work was to optimize a radial EPI [3] techniq...

متن کامل

3D Coronary MRA with 2D beat-to-beat translational and bin-to-bin affine respiratory motion correction using a golden radial image navigator

Figure 2 – Reformatted images showing the main coronary arteries of two subjects. Subject 1: 2D Affine + translational motion correction gives superior image quality compared to both 2D translational correction and a gated scan (with ~3x reduction in scan time). Subject 2: 2D motion correction gives similar image quality to the gated scan with ~2x reduction in scan time. Affine correction shows...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010