Characterization and Energy Calibration of a Silicon-Strip Detector for Photon-Counting Spectral Computed Tomography
نویسنده
چکیده
Multibin photon-counting x-ray detectors are promising candidates to be applied in next generation computed tomography (CT), whereby energy information from a broad x-ray spectrum can be extracted and properly used for improving image quality and correspondingly reducing radiation dose. A silicon-strip detector has been developed for spectral CT, which operates in photon-counting mode and allows pulse-height discrimination with 8 adjustable energy bins. Critical characteristics, energy resolution and count-rate performance, of the detector are evaluated. An absolute energy resolution (σE) from 1.5 keV to 1.9 keV with increasing x-ray energy from 40 keV to 120 keV is found. Pulse pileup degrades the energy resolution by 0.4 keV when increasing the input count rate from zero to 100 Mcps mm, while charge sharing shows negligible effect. A near linear relationship between the input and output count rates is observed up to 90 Mcps mm in a clinical CT environment. In addition, no saturation effect appears for the maximally achieved photon flux of 485 Mphotons s mm with a count rate loss of 30%. The detector is energy calibrated in terms of gain and offset with the aid of monoenergetic x rays. The gain variation among channels is below 4%, whereas the variation of offsets is on the order of 1 keV. In order to do the energy calibration in a routinely available way, a method that makes use of the broad x-ray spectrum instead of using monoenergetic x rays is proposed. It is based on a regression analysis that adjusts a modelled spectrum of deposited energies to a measured pulse-height spectrum. Application of this method shows high potential to be applied in an existing CT scanner with an uncertainty of a calibrated threshold between 0.1 and 0.2 keV. The energy-calibration method is further used in the development of a spectral response model of the detector. This model is used to accurately bin-wise predict the response of each detector channel, which is validated by two application examples. First, the model is used in combination with the inhomogeneity compensation method to eliminate ring artefacts in CT images. Second, the spectral response model is used as the basis of the maximum likelihood approach for projection-based material decomposition. The reconstructed basis images show a good separation between the calcium-like material and the contrast agents, iodine and gadolinium. Additionally, the contrast agent concentrations are reconstructed with more than 94% accuracy.
منابع مشابه
Characterization and Optimization of Silicon-strip Detectors for Mammography and Computed Tomography
The goal in medical x-ray imaging is to obtain the image quality required for a given detection task, while ensuring that the patient dose is kept as low as reasonably achievable. The two most common strategies for dose reduction are: optimizing incident x-ray beams and utilizing energy information of transmitted beams with new detector techniques (spectral imaging). In this thesis, dose optimi...
متن کاملSpectral Computed Tomography with a Photon-Counting Silicon-Strip Detector
Computed tomography (CT) is a widely used medical imaging modality. By rotating an x-ray tube and an x-ray detector around the patient, a CT scanner is able to measure the x-ray transmission from all directions and form an image of the patient’s interior. CT scanners in clinical use today all use energy-integrating detectors, which measure the total incident energy for each measurement interval...
متن کاملEnergy-resolved CT imaging with a photon-counting silicon-strip detector.
Photon-counting detectors are promising candidates for use in the next generation of x-ray computed tomography (CT) scanners. Among the foreseen benefits are higher spatial resolution, better trade-off between noise and dose and energy discriminating capabilities. Silicon is an attractive detector material because of its low cost, mature manufacturing process and high hole mobility. However, it...
متن کاملReconstruction of spectral CT images
X-ray computed tomography (CT) is a medical imaging modality that allows reconstruction of the internal stucture of the human body from a large number of x-ray attenuation measurements. In recent years, the development of spectral CT, in which the energy dependence of the x-ray attenuation coe cient is utilized, has attracted considerable interest. This thesis is concerned with a spectral CT sy...
متن کاملEnergy Calibration of a CdTe Photon Counting Spectral Detector with Consideration of its Non-Convergent Behavior
Fast and accurate energy calibration of photon counting spectral detectors (PCSDs) is essential for their biomedical applications to identify and characterize bio-components or contrast agents in tissues. Using the x-ray tube voltage as a reference for energy calibration is known to be an efficient method, but there has been no consideration in the energy calibration of non-convergent behavior ...
متن کامل