Navigated Acetabular Cup Fixation for Acetabular Deformity or Revision Total Hip Arthroplasty
نویسندگان
چکیده
PURPOSE To evaluate the usefulness of navigated acetabular cup fixation for total hip arthroplasty in patients with acetabular deformity or revision total hip arthroplasty. MATERIALS AND METHODS This study enrolled 28 patients with at least 12 months' follow-up. The safe zone of the acetabular cup was defined as 40°±10°in inclination and 15°±10°in anteversion. The authors used the navigation and radiographic data to determine whether the acetabular cup was located within the safe zone or not. To evaluate the clinical outcomes, preoperative and last follow-up Harris hip scores were checked, and the occurrence of complications was evaluated. RESULTS According to the navigation data, the mean inclination and anteversion were 38.5°±4.7°(range, 32°-50°) and 16.6°±4.0°(range, 8°-23°), respectively. According to the radiographic data the mean inclination and anteversion were 40.5°±4.6°(range, 32°-50°) and 19.4°±4.2°(range, 8°-25°), respectively. In both cases, all values were within the safe zone. Harris hip score was improved in all patients from preoperative 52.3±14.4 points (range, 29-87 points) to 88.0±9.0 points (range, 65-99 points) at the last follow-up. There was no dislocation or loosening of both cases. CONCLUSION Navigated acetabular cup fixation is a useful technique for total hip arthroplasty in patients with acetabular deformity or revision total hip arthroplasty because it prevents the malposition and related complications.
منابع مشابه
Acetabular Cup Revision
The use of acetabular cup revision arthroplasty is on the rise as demands for total hip arthroplasty, improved life expectancies, and the need for individual activity increase. For an acetabular cup revision to be successful, the cup should gain stable fixation within the remaining supportive bone of the acetabulum. Since the patient's remaining supportive acetabular bone stock plays an importa...
متن کاملComparative Study of Peripheral Rim Fixation Using Jumbo Cup in Revisional Hip Arthroplasty
PURPOSE It is challenging procedure to revise acetabular component in acetabulum with severe bone defect or deformity. The jumbo cup is good option for revisional arthroplasty in large bone defect. The purpose of this study is to compare the prognosis of revisional total hip arthroplasty using jumbo cup with peripheral rim fixation and no rim fixation. MATERIALS AND METHODS We included the pa...
متن کاملEarly Clinical Outcomes with a 3-D Porous Titanium Acetabular Cup
Cementless acetabular components are associated with a significant incidence of polyethylene wear and secondary osteolysis. 3-dimentional (3-D) porous coating and enhanced shell to a liner fixation are expected to reduce the polyethylene wear and to increase the longevity of an acetabular cup. The authors report the early clinical outcome with a cementless acetabular cup, Regenerex Ringloc+ (Zi...
متن کاملAcetabular Reconstruction in Total Hip Arthroplasty
The difficulties encountered in dealing with the bone deficient acetabulum are amongst the greatest challenges in hip surgery. Acetabular reconstruction in revision total hip arthroplasty can successfully be achieved with hemispherical components featuring a porous or roughened ingrowth surface and options for placement of multiple screws for minor acetabular defect. Acetabular component select...
متن کاملInfluence of cementless cup surface on stability and bone fixation 2 years after total hip arthroplasty.
Loss of fixation between bone and implant surface is one of the main treatment problems in total hip arthroplasty. It might lead to implant instability, bone loss and treatment failure resulting in revision surgery. Surface modification is a method for improving bone response to implant and increasing implant osseointegration. However, the currently applied modifications such as hydroxyapatite ...
متن کامل