NCO-sP(EO-stat-PO) Coatings on Gold Sensors—a QCM Study of Hemocompatibility
نویسندگان
چکیده
The reliability of implantable blood sensors is often hampered by unspecific adsorption of plasma proteins and blood cells. This not only leads to a loss of sensor signal over time, but can also result in undesired host vs. graft reactions. Within this study we evaluated the hemocompatibility of isocyanate conjugated star shaped polytheylene oxide-polypropylene oxide co-polymers NCO-sP(EO-stat-PO) when applied to gold surfaces as an auspicious coating material for gold sputtered blood contacting sensors. Quartz crystal microbalance (QCM) sensors were coated with ultrathin NCO-sP(EO-stat-PO) films and compared with uncoated gold sensors. Protein resistance was assessed by QCM measurements with fibrinogen solution and platelet poor plasma (PPP), followed by quantification of fibrinogen adsorption. Hemocompatibility was tested by incubation with human platelet rich plasma (PRP). Thrombin antithrombin-III complex (TAT), β-thromboglobulin (β-TG) and platelet factor 4 (PF4) were used as coagulation activation markers. Furthermore, scanning electron microscopy (SEM) was used to visualize platelet adhesion to the sensor surfaces. Compared to uncoated gold sensors, NCO-sP(EO-stat-PO) coated sensors revealed significant better resistance against protein adsorption, lower TAT generation and a lower amount of adherent platelets. Moreover, coating with ultrathin NCO-sP(EO-stat-PO) films creates a cell resistant hemocompatible surface on gold that increases the chance of prolonged sensor functionality and can easily be modified with specific receptor molecules.
منابع مشابه
NCO-sP(EO-stat-PO) surface coatings preserve biochemical properties of RGD peptides.
We have previously reported that star shaped poly(ethylene oxide-stat-propylene oxide) macromers with 80% EO content and isocyanate functional groups at the distal ends [NCO-sP(EO-stat-PO)] can be used to generate coatings that are non-adhesive but easily functionalized for specific cell adhesion. In the present study, we investigated whether the NCO-sP(EO-stat-PO) surfaces maintain peptide con...
متن کاملAdsorption of PEO-PPO-PEO triblock copolymers with end-capped cationic chains of poly(2-dimethylaminoethyl methacrylate).
We study the adsorption of a symmetric triblock copolymer of ethylene oxide, EO, and propylene oxide, PO, end-capped with quarternized poly(2-dimethylaminoethyl methacrylate), DMAEMA (DMAEMA(24)-EO(132)PO(50)EO(132)-DMAEMA(24)). Light scattering and tensiometry are used to measure the relative size of the associated structures and surface excess at the air-liquid interface. The adsorbed amount,...
متن کاملAdsorption of a nonionic symmetric triblock copolymer on surfaces with different hydrophobicity.
This study investigates the adsorption of a symmetric triblock nonionic polymer comprising ethylene oxide (EO) and propylene oxide (PO) blocks (Pluronic P-105, EO(37)PO(56)EO(37)) on a range of substrates including hydrophobic, i.e., polypropylene (PP), poly(ethylene terephthalate) (PET), nylon, and graphite, and hydrophilic, i.e., cellulose and silica. The adsorption process and the structure ...
متن کاملPreliminary Study of a Prototype Methyl - Mercury Monitor for In - Field Pore Water Sample Analyses – 11559
This study involves proof-of-concept research for an innovative, low-cost, and portable methylmercury (MeHg) monitor to be utilized at Oak Ridge Reservation (ORR) creek beds. The MeHg monitor comprises three primary steps: (1) chemical derivatization; (2) preconcentration using the purge-and-trap (P&T) method; and (3) sensing using Quartz Crystal Microbalance (QCM) sensors. This preliminary stu...
متن کاملUtilisation of Quartz Crystal Microbalance Sensors with Dissipation (QCM-D) for a Clauss Fibrinogen Assay in Comparison with Common Coagulation Reference Methods
The determination of fibrinogen levels is one of the most important coagulation measurements in medicine. It plays a crucial part in diagnostic and therapeutic decisions, often associated with time-critical conditions. The commonly used measurement is the Clauss fibrinogen assay (CFA) where plasma is activated by thrombin reagent and which is conducted by mechanical/turbidimetric devices. As qu...
متن کامل