Prevention of catheter-related blood stream infection: back to basics?
نویسندگان
چکیده
BACKGROUND Central venous catheter (CVC)-related infections are a substantial problem in the intensive care unit (ICU). Our infection control team initiated the routine use of antiseptic-coated (chlorhexidine-silver sulfadiazine; Chx-SS) CVCs in our adult ICUs to reduce catheter-associated (CA) and catheter-related (CR) blood stream infection (BSI) as we implemented other educational and best practice standardization strategies. Prior randomized studies documented that the use of Chx-SS catheters reduces microbial colonization of the catheter compared with an uncoated standard (Std) CVC but does not reduce CR-BSI. We therefore implemented the routine use of uncoated Std CVCs in our surgical ICU (SICU) and examined the impact of this change. HYPOTHESIS The use of uncoated Std CVCs does not increase CR-BSI rate in an SICU. METHODS Prospective evaluation of universal use of uncoated Std CVCs, implemented November 2007 in the SICU. The incidences of CA-BSI and CR-BSI were compared during November 2006-October 2007 (universal use of Chx-SS CVCs) and November 2007-October 2008 (universal use of Std CVCs) by t-test. The definitions of the U.S. Centers for Disease Control and Prevention were used for CA-BSI and CR-BSI. Patient data were collected via a dedicated Acute Physiology and Chronic Health Evaluation (APACHE) III coordinator for the SICU. RESULTS Annual use of CVCs increased significantly in the last six years, from 3,543 (2001) to 5,799 (2006) total days. The APACHE III scores on day 1 increased from a mean of 54.4 in 2004 to 55.6 in 2008 (p = 0.0010; 95% confidence interval [CI] 1.29-5.13). The mean age of the patients was unchanged over this period, ranging from 58.2 to 59.6 years. The Chx-SS catheters were implemented in the SICU in 2002. Data regarding the specific incidence of CR-BSI were collected beginning at the end of 2005, with mandatory catheter tip cultures when CVCs were removed. Little difference was identified in the incidence of BSI between the interval with universal Chx-SS use and that with Std CVC use. (Total BSI 0.7 vs. 0.8 per 1,000 catheter days; CA-BSI 0.5 vs. 0.8 per 1,000 catheter days; CR-BSI 0.2 vs. 0 per 1,000 catheter days.) No difference was seen in the causative pathogens of CA-BSI or CR-BSI. CONCLUSION Eliminating the universal use of Chx-SS-coated CVCs in an SICU with a low background incidence of CR-BSIs did not result in an increase in the rate of CR-BSIs. This study documents the greater importance of adherence to standardization of the processes of care related to CVC placement than of coated CVC use in the reduction of CR-BSI.
منابع مشابه
Implantable Port Devices, Complications and outcome in Pediatric Cancer, a Retrospective Study
Abstract Background Peripheral blood vessels, due to availability are used for many years in cancer patients, however in patients with potentially harmful drugs to skin (vesicant drugs) or difficult accessibility to vessels, the use of implantable port (totally implantable venous access port-TIVAP)devices with central vascular access are important. ...
متن کاملThe Impact of Intraluminal Vancomycin Adminstration on Prevention of Hemodialysis CatheterRelated Infections
Introduction: Percutaneously inserted double-lumen central venous hemodialysis catheters provide the nephrologist with an excellent temporary access for an immediate hemodialysis treatment and preserve the peripheral veins for the future creation of a permanent arteriovenous vascular access. Unfortunately catheterrelated infections are usually common. In this study, the impact of intra luminal ...
متن کاملمیزان بروز عفونت های خونی و ادراری در بیماران سوخته بستری شده در مرکز سوختگی قطب الدین شیراز در سال های 80-1379
Background and purpose: Though burn wound infections have been extensively studied, but other nosocomial infections in burn patients have received less attention. Ïnvasive diagnostic procedures (vascular and bladder catheterization) make the burn patients more susceptible to different nosocomial infections. The aim of this study was to determine the incidence rates of blood stream and urinary...
متن کاملA randomised controlled trial of Heparin versus EthAnol Lock THerapY for the prevention of Catheter Associated infecTion in Haemodialysis patients – the HEALTHY-CATH trial
BACKGROUND Tunnelled central venous dialysis catheter use is significantly limited by the occurrence of catheter-related infections. This randomised controlled trial assessed the efficacy of a 48 hour 70% ethanol lock vs heparin locks in prolonging the time to the first episode of catheter related blood stream infection (CRBSI). METHODS Patients undergoing haemodialysis (HD) via a tunnelled c...
متن کاملffect of Chlorhexidine on Prevention of Local Infection in Temporary Transvenous Pacemaker Catheter Site
Background and Objectives: The local infection of temporary transvenous pacemaker catheter site is a common hospital acquired infections. This study aimed to assess the effect of the Chlorhexidine Glaciate 2% on prevention of local infection on temporary transvenous pacemaker catheter site. Materials and Methods: In this 7-month randomized controlled trial, 100 patients having temporary transve...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Surgical infections
دوره 12 1 شماره
صفحات -
تاریخ انتشار 2011