Revision of shoulder replacement with a reversed shoulder prosthesis (Delta III): report of five cases.
نویسندگان
چکیده
The authors report on their experience in revision total shoulder arthroplasty using the Delta III shoulder prosthesis, a reversed constrained prosthesis which is known to give good functional results in the rotator cuff-deficient shoulder. It was implanted in patients with a failed total or hemishoulder prosthesis. The Constant-Murley score was used to assess the functional outcome. The preliminary results achieved in four patients (one bilaterally) are discussed and compared with the results of other treatments. After two years follow-up, the Constant-Murley score has improved from 14/100 preoperatively to 62/100 postoperatively. Although these initially good functional results may be temporary and loosening may occur over the longer term, the authors recommend the Delta III shoulder prosthesis as an alternative solution for revision shoulder arthroplasty.
منابع مشابه
The Midterm Results of the Delta Xtend Reverse Shoulder System: A Five-Year Outcome Study
Background: The purpose of this study was to examine the mid-term functional outcomes, radiographic results,and revision rates of patients treated with the Delta Xtend Reverse Shoulder System for both primary and revisionarthroplasty indications.Methods: A retrospective review was conducted of records for all individuals who underwent a reverse shoulderarthroplasty using the Delta Xtend Reverse...
متن کاملSix-year experience with the Delta III reverse shoulder prosthesis.
PURPOSE To report the clinical and radiographic results and complications of the Delta III reverse prosthesis. METHODS 24 women and 2 men aged 62 to 84 (mean, 75) years underwent total shoulder replacement using the Delta III reverse prosthesis. Patient diagnoses were massive rotator cuff tear (n=20), disabling sequelae of proximal humeral fractures (n=3), and failure of an unconstrained arth...
متن کاملRisk factors for revision after shoulder arthroplasty
BACKGROUND AND PURPOSE Previous studies on shoulder arthroplasty have usually described small patient populations, and few articles have addressed the survival of shoulder implants. We describe the results of shoulder replacement in the Norwegian population (of 4.7 million) during a 12-year period. Trends in the use of shoulder arthroplasty during the study period were also investigated. PATI...
متن کاملTreatment of rotator cuff arthropathy with a reversed Delta shoulder prosthesis.
The treatment of rotator cuff arthropathy is still a matter of debate. Up to now a hemiarthroplasty was usually used. We report the results obtained with a reversed shoulder prosthesis (Delta prosthesis, De Puy) in seven patients with severe rotator cuff arthropathy. The mean Constant score increased from 17.9/100 preoperatively to 56.7/100 postoperatively. The mean follow-up was 16 months. Loo...
متن کاملRevision of Anatomic Total Shoulder Arthroplasty to Hemiarthroplasty: Does it work?
Background: The projected increase in revision shoulder arthroplasty has increased interest in the outcomes of theseprocedures. Glenoid component removal and conversion to a hemiarthroplasty (HA) is an option for aseptic glenoidloosening after anatomic total shoulder arthroplasty (aTSA).Methods: We identified patients who had undergone revision shoulder arthroplasty over a 15-...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Acta orthopaedica Belgica
دوره 67 4 شماره
صفحات -
تاریخ انتشار 2001