Treatment outcome and efficacy of an aligner technique – regarding incisor torque, premolar derotation and molar distalization

نویسندگان

  • Mareike Simon
  • Ludger Keilig
  • Jörg Schwarze
  • Britta A Jung
  • Christoph Bourauel
چکیده

BACKGROUND The aim of this study was to investigate the efficacy of orthodontic treatment using the Invisalign® system. Particularly, we analyzed the influence of auxiliaries (Attachment/Power Ridge) as well as the staging (movement per aligner) on treatment efficacy. METHODS We reviewed the tooth movements of 30 consecutive patients who required orthodontic treatment with Invisalign®. In all patients, one of the following tooth movements was performed: (1) Incisor Torque >10°, (2) Premolar derotation >10° (3) Molar distalization >1.5 mm. The groups (1)-(3) were subdivided: in the first subgroup (a) the movements were supported with the use of an attachment, while in the subgroup (b) no auxiliaries were used (except incisor torque, in which Power Ridges were used). All tooth movements were performed in a split-mouth design. To analyze the clinical efficacy, pre-treatment and final plaster cast models were laser-scanned and the achieved tooth movement was determined by way of a surface/surface matching algorithm. The results were compared with the amount of tooth movement predicted by ClinCheck®. RESULTS The overall mean efficacy was 59% (SD = 0.2). The mean accuracy for upper incisor torque was 42% (SD = 0.2). Premolar derotation showed the lowest accuracy with approximately 40% (SD = 0.3). Distalization of an upper molar was the most effective movement, with efficacy approximately 87% (SD = 0.2). CONCLUSION Incisor torque, premolar derotation and molar distalization can be performed using Invisalign® aligners. The staging (movement/aligner) and the total amount of planned movement have an significant impact on treatment efficacy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Forces and moments generated by removable thermoplastic aligners.

INTRODUCTION The exact force systems as well as their progressions generated by removable thermoplastic appliances have not been investigated. Thus, the purposes of this experimental study were to quantify the forces and moments delivered by a single aligner and a series of aligners (Invisalign; Align Technology, Santa Clara, Calif) and to investigate the influence of attachments and power ridg...

متن کامل

مقایسه زوایای tip و torque دندانها در بیماران پس از درمان ارتدنسی و افراد دارای اکلوژن نرمال

The angle of long axis of tooth crown is called tip in mesiodostal and torque in faciolingual direction. Both have special importance for producing an ideal occlusion. The aim of the present study was determination of the average tip and torque of each permanent tooth in well treated patients with edgewise system compare to control group with normal occlusion. In this stu...

متن کامل

Effects of Jones Jig Appliance in Maxillary First Molar Distalization

The purpose of this study was to evaluate treatment effects of Jones jig appliance during class-II molar correction with a focus on the magnitude of maxillary first molar distalization, its tipping, extrusion and rotation as well as anchorage loss at premolarincisor unit. A complete set of pre and post distalization records including history, clinical examination, Lateral cephalometric radiogra...

متن کامل

Effects of Distal Jet Appliance in Class-ii Molar Correction

This study was conducted on a sample of thirty patients selected from Orthodontics department de’Montmorency College of dentistry/ Punjab dental Hospital, Lahore. The purpose of study was to evaluate treatment effects of Distal Jet Appliance during Class-II molar correction with a focus on the magnitude of Maxillary first molar distalization, its tipping, extrusion, rotation as well as anchorag...

متن کامل

Use of the intraosseous screw for unilateral upper molar distalization and found well balanced occlusion

BACKGROUND The aim of this study was to present a temporary anchorage device with intraosseous screw for unilateral molar distalization to make a space for the impacted premolar and to found well balanced occlusion in a case. CASE PRESENTATION A 13-year-old male who have an impacted premolar is presented with skeletal Class I and dental Class 2 relationship. The screw was placed and immediate...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 14  شماره 

صفحات  -

تاریخ انتشار 2014