Screening of folate status with use of dried blood spots on filter paper.

نویسندگان

  • S D O'Broin
  • E W Gunter
چکیده

BACKGROUND Dried blood spots (DBS) on filter paper have been a successful and economical matrix for neonatal screening. OBJECTIVE Our objective was to develop and evaluate an optimized method for DBS folate analysis and to assess DBS folate stability. DESIGN DBS were eluted from paper by sonication in 5 g ascorbic acid/L containing 0.1% (by vol) Triton X-100 and hemoglobin folate values (HF; as pmol/g) were calculated from DBS eluate folate and hemoglobin concentrations. RESULTS Over 95% of DBS folate was eluted during a standardized sonication cycle and DBS folate assay reproducibility was acceptable both within (CV: <8%) and between (CV: <9%) runs. HF means (+/-1 SD) from finger-stick DBS and conventional venous methods were 2513 +/- 1144 and 2607 +/- 1195 pmol/g, respectively, in blood samples taken concurrently from 80 donors, and they correlated well (r = 0.97, P < 0.001). HF values and erythrocyte folate measures may be interconverted by using the mean cell hemoglobin concentration. CONCLUSION The DBS matrix has potential as an inexpensive and practical option for folate screening studies.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quantitation of 5-Methyltetrahydrofolic Acid in Dried Blood Spots and Dried Plasma Spots by Stable Isotope Dilution Assays

Because of minimal data available on folate analysis in dried matrix spots (DMSs), we combined the advantages of stable isotope dilution assays followed by LC-MS/MS analysis with DMS sampling to develop a reliable method for the quantitation of plasma 5-methyltetrahydrofolic acid in dried blood spots (DBSs) and dried plasma spots (DPSs) as well as for the quantitation of whole blood 5-methyltet...

متن کامل

Comprehensive Mu-opioid-receptor Genotyping

References 1. Carpenter KH, Wiley V. Application of tandem mass spectrometry to biochemical genetics and newborn screening. Clin Chim Acta 2002;322:1–10. 2. Carreiro-Lewandowski E. Newborn screening: an overview. Clin Lab Sci 2002;15:229–30. 3. Jones PM, Bennett MJ. The changing face of newborn screening: diagnosis of inborn errors of metabolism by tandem mass spectrometry. Clin Chim Acta 2002;...

متن کامل

Radioimmunoassay of "free thyroxin" in dried blood spots on filter paper - preliminary observations on the effective differentiation of subjects with congenital hypothyroidism from those with subnormal thyroxin-binding globulin and normal subjects.

In this sensitive, simple method for measuring "free thyroxin" (FT4) in eluates of dried blood spots on filter paper by use of a radioimmunoassay kit (Amerlex Free T4 RIA), the measurable range of FT4 is 1.8 to 57 ng/L (equivalent to the concentration in serum), or 7 to 237 fg/tube. The mean coefficients of variation for within assay-within spots, within assay-between spots, and between assays ...

متن کامل

Rapid DNA Extraction from Dried Blood Spots on Filter Paper: Potential Applications in Biobanking

OBJECTIVES Dried blood spot (DBS) technology is a microsampling alternative to traditional plasma or serum sampling for pharmaco- or toxicokinetic evaluation. DBS technology has been applied to diagnostic screening in drug discovery, nonclinical, and clinical settings. We have developed an improved elution protocol involving boiling of blood spots dried on Whatman filter paper. METHODS The pu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The American journal of clinical nutrition

دوره 70 3  شماره 

صفحات  -

تاریخ انتشار 1999