Three waveforms for transthoracic defibrillation are assessed and compared: the Pulsed Biphasic Waveform (PBW), the Rectilinear Biphasic Waveform (RBW), and the “lossless” constant current (LLCC) pulses. Two indices are introduced: 1) kf = W/W0 – the ratio between the delivered energy W and the energy W0 of a rectangular pulse with the same duration and electric charge; 2) ηC = W/WC0 – the level of utilizing the initially loaded capacitor energy WC0. The envisioned comparative study shows that ηC index is favorable for both PBW and LLCC, while kf of both RBW and LLCC demonstrates advantage over the PBW in the range of small inter-electrode thoracic impedances below 80 Ω. Some design considerations are also discussed. The attractive LLCC concept needs large and heavy inductive coil to support the constant current amplitude, besides it is capable to induce strong electromagnetic influences due to the complex current control. The RBW technology controls the delivery of current through a series of internal resistors which are, however, a source of high heat losses. The PBW implements controlled duty cycle of high-frequency chopped pulses to adapt the energy delivery in respect of the patient impedance measured at the beginning of the shock. PBW technology makes use of small capacitors which allows the construction of light weight and small-size portable devices for transthoracic defibrillation. Obviously, there is no outstanding optimal defibrillation waveform, however, the PBW technology reveals some advantages.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimization of biphasic waveforms for human nonthoracotomy defibrillation.

BACKGROUND Biphasic waveforms reduce defibrillation threshold (DFT) in a wide variety of models. Although there are several human studies of long-duration, high-tilt biphasic waveform defibrillation, the specific biphasic waveform shape required to achieve optimal DFT reduction is unknown. METHODS AND RESULTS This study tested the effect of single capacitor biphasic waveform tilt modification...

متن کامل

Comparison of a novel rectilinear biphasic waveform with a damped sine wave monophasic waveform for transthoracic ventricular defibrillation. ZOLL Investigators.

OBJECTIVES We compared the efficacy of a novel rectilinear biphasic waveform, consisting of a constant current first phase, with a damped sine wave monophasic waveform during transthoracic defibrillation. BACKGROUND Multiple studies have shown that for endocardial defibrillation, biphasic waveforms have a greater efficacy than monophasic waveforms. More recently, a 130-J truncated exponential...

متن کامل

Improved safety factor for triphasic defibrillator waveforms.

Newly developed biphasic waveforms improve defibrillation efficacy both by reduction of defibrillation threshold and by amelioration of shock-induced dysfunction depending on the relative shape of the first and second pulses. Each of these independent effects improves the waveform's safety factor, the ratio between the shock intensity that produces a specific degree of postshock dysfunction and...

متن کامل

Importance of using biphasic shock waveforms for cardioversion from atrial fibrillation: an unresolved issue.

Correspondence to: Dr John M Morgan, Southampton University Hospitals, Southampton, SO16 6UY, UK; jmm@ cardiology.co.uk . . . . . . . . . . . . . . . . . . . . . . . I n a previous issue of Heart, Scholten and colleagues presented data to show that a biphasic external atrial defibrillation shock waveform offers no significant advantage over a monophasic shock waveform in current clinical practi...

متن کامل

Arrhythmia/Electrophysiology Ascending-Ramp Biphasic Waveform Has a Lower Defibrillation Threshold and Releases Less Troponin I Than a Truncated Exponential Biphasic Waveform

Background—We tested the hypothesis that the shape of the shock waveform affects not only the defibrillation threshold but also the amount of cardiac damage. Methods and Results—Defibrillation thresholds were determined for 11 waveforms—3 ascending-ramp waveforms, 3 descending-ramp waveforms, 3 rectilinear first-phase biphasic waveforms, a Gurvich waveform, and a truncated exponential biphasic ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013