Simultaneous Estimation of Telmisartan and Amlodipine Besylate in Pharmaceutical Dosage Form by Rp – Hplc

نویسندگان

  • Paul Richards
  • Karunakar Reddy
چکیده

The chromatographic analysis was performed on ODS symmetry C18 column (150 × 4.6 mm, 5 μ particle size) with mobile phase consisting of acetonitrile and phosphate buffer (pH 4.0) in the ratio of 60:40 v/v, at a flow rate of 1.2 mL/min and eluents monitored at 237 nm. The method was validated for linearity, accuracy, precision, robustness and application for assay as per International Conference on Harmonization (ICH) guidelines. The retention times of amlodipine besylate and telmisartan were 2.633 and 5.600 min, respectively. The calibration curves of peak area versus concentration, which was linear from 2.5-15 μg/mL for amlodipine besylate and 20-120 μg/mL for telmisartan, had regression coefficient (r) greater than 0.999. The method had the requisite accuracy, precision, and robustness for simultaneous determination of amlodipine besylate and telmisartan in tablets. The proposed method is simple, economical, accurate and precise, and could be successfully employed in routine quality control for the simultaneous analysis of amlodipine besylate and telmisartan in tablets.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simultaneous estimation of amlodipine besylate and nebivolol hydrochloride in pharmaceutical tablets formulation by RP-HPLC using PDA detector

Background: The present work was undertaken with the aim to develop and validate a rapid and consistent RP-HPLC method in which the peaks will be appear with short period of time as per ICH Guidelines. Materials and Methods: The separation was achieved on a a stainless steel analytical column, Eclipse XDB plus C18 column (4.6 X 150 mm; 5 μm) in an isocratic mode. The mobile phase w...

متن کامل

Development and Validation of RP-HPLC Method for Simultaneous Estimation of Enalapril Maleate and Amlodipine Besylate in Combined Dosage form

Article history: Received on: 08/09/2012 Revised on: 19/09/2012 Accepted on: 24/09/2012 Available online: 28/09/2012 A simple, precise and rapid reverse-phase HPLC method has been developed and subsequently validated for the simultaneous estimation of Amlodipine besylate and Enalapril maleate from their combination drug product. The proposed RP-HPLC method utilizes a Phenomenex C18, 5 μm, 250 m...

متن کامل

Simultaneous estimation of amlodipine besylate and nebivolol hydrochloride in combined dosage form by RP-HPLC

A simple, selective, rapid, precise and economical reverse phase HPLC method has been developed for the simultaneous estimation of Amlodipine Besylate and Nebivolol hydrochloride in pharmaceutical dosage forms. The method was carried out on a Luna C-18, 5 μ column with a mobile phase consisting of 0.005M ammonium acetate solution, acetonitrile and triethylamine in the ratio 60:40:0.1 (v/v) and ...

متن کامل

SIMULTANEOUS ESTIMATION OF AMLODIPINE BESYLATE AND HYDROCHLORTHIAZIDE IN TABLET DOSAGE FORM BY RP-HPLC M.V.Kumudhavalli*, K.Anand babu, B.Jayakar

A simple, precise, rapid and accurate RP-HPLC method has been developed for the simultaneous estimation of Amlodipine besylate and Hydrochlorthiazide in tablet formulations. The chromatographic separation was achieved on a Shimadzu Symmetry C18 column (250 mm x 4.6mm, 5.0 μ particle size) using Methanol: Acetonitrile: 50mM Na2HPO4 pH7.0 (60:20:20v/v/v) with 1% triethylamine. Flow rate was 1ml/m...

متن کامل

Development and Validation of Rp-hplc Method for Simultaneous Estimation of Lisinopril and Amlodipine Besylate in Tablet Dosage Form

A simple, specific, precise, and accurate reversed-phase HPLC method was developed and validated for simultaneous estimation of lisinopril and amlodipine besylate in tablet dosage forms. The separation was achieved by Hypersil ODS-BP C18 column (250 mm × 4.6 mm; 5.0 μm) using methanol: phosphate buffer at pH 6 adjusted with orthophosphoric acid (30: 70, v/v) as eluent, at a flow rate of 1 mL/mi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2011