Pilot evaluation of a prototype critical care blood glucose monitor in normal volunteers.

نویسندگان

  • Marc C Torjman
  • Michael E Goldberg
  • Jeffrey J Littman
  • Robert A Hirsh
  • Richard P Dellinger
چکیده

BACKGROUND Availability of a highly accurate in-hospital automated blood glucose (BG) monitor could facilitate implementation of intensive insulin therapy protocols through effective titration of insulin therapy, improved BG control, and avoidance of hypoglycemia. We evaluated a functional prototype BG monitor designed to perform frequent automated blood sampling for glucose monitoring. METHODS Sixteen healthy adult volunteer subjects had intravenous catheter insertions in a forearm or hand vein and were studied for 8 hours. The prototype monitor consisted of an autosampling unit with a precise computer-controlled reversible syringe pump and a glucose analytical section. BG was referenced against a Yellow Springs Instrument (YSI) laboratory analyzer. Sampling errors for automated blood draws were assessed by calculating the percent of failed draws, and BG data were analyzed using the Bland and Altman technique. RESULTS Out of 498 total sample draws, unsuccessful draws were categorized as follow: 11 (2.2%) were due to autosampler technical problems, 21 (4.2%) were due to catheter-related failures, and 37 (7.4%) were BG meter errors confirmed by a glucometer-generated error code. Blood draw difficulties or failures related to the catheter site (e.g., catheter occlusion or vein collapse) occurred in 6/15 (40%) subjects. Mean BG bias versus YSI was 0.20 +/- 12.6 mg/dl, and mean absolute relative difference was 10.4%. CONCLUSIONS Automated phlebotomy can be performed in healthy subjects using this prototype BG monitor. The BG measurement technology had suboptimal accuracy based on a YSI reference. A more accurate BG point-of-care testing meter and strip technology have been incorporated into the future version of this monitor. Development of such a monitor could alleviate the burden of frequent BG testing and reduce the risk of hypoglycemia in patients on insulin therapy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Analytical Performance and Quality Control of a Glucose Monitor System

  Background and Objective: The reliability and validity of monitors for self-monitoring of blood glucose are debated. We evaluated the analytical performance of Accu-check Active (Boehringer Mannheim, Roche) which is one of the most commonly used monitors in Iran. Material and Methods: We compared the monitor readings with the reference values by percentage of values within...

متن کامل

Noninvasive blood glucose monitoring with optical coherence tomography: a pilot study in human subjects.

OBJECTIVE To study the feasibility of noninvasive blood glucose monitoring using optical coherence tomography (OCT) technique in healthy volunteers. RESEARCH DESIGN AND METHODS An OCT system with the wavelength of 1,300 nm was used in 15 healthy subjects in 18 clinical experiments. Standard oral glucose tolerance tests were performed to induce changes in blood glucose concentration. Blood sam...

متن کامل

Teaching in the Laboratory Blood glucose monitoring as a teaching tool for endocrinology: a new perspective

Moats RK II. Blood glucose monitoring as a teaching tool for endocrinology: a new perspective. Adv Physiol Educ 33: 209–212, 2009; doi:10.1152/advan.00009.2009.—The education of new allied health professionals and nurses in proper endocrine evaluation and care has become critical in recent years, especially considering the greatly increased prevalence of diabetes in adults and children. The eva...

متن کامل

A novel noninvasive blood glucose monitor.

OBJECTIVE To evaluate the precision and accuracy of a new advanced prototype of a noninvasive blood glucose monitor across a wide range of serum glucose concentrations. RESEARCH DESIGN AND METHODS An advanced handheld noninvasive glucose monitor prototype was calibrated and tested using patients recruited by the General Research Center of the University of Connecticut Health Center. The monit...

متن کامل

Blood glucose monitoring as a teaching tool for endocrinology: a new perspective.

The education of new allied health professionals and nurses in proper endocrine evaluation and care has become critical in recent years, especially considering the greatly increased prevalence of diabetes in adults and children. The evaluation of blood glucose levels in human volunteers over time is a powerful teaching tool for endocrinology that has the added benefit of exposing the student to...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of diabetes science and technology

دوره 3 6  شماره 

صفحات  -

تاریخ انتشار 2009