Physiological Noise in Gradient Echo and Spin Echo EPI at 3T and 7T

نویسندگان

  • C. Triantafyllou
  • J. R. Polimeni
  • M. Elschot
  • L. L. Wald
چکیده

C. Triantafyllou, J. R. Polimeni, M. Elschot, and L. L. Wald A.A. Martinos Imaging Center, McGovern Institute for Brain Research, MIT, Cambridge, MA, United States, A.A. Martinos Center for Biomedical Imaging, Department of Radiology, MGH, Charlestown, MA, United States, Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, Netherlands, Harvard-MIT Division of Health Sciences and Technology, MIT, Cambridge, MA, United States

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimisation of the combined gradient echo/spin echo (GESE) sequence for the measurement of T2 at 7.0 T

The combined gradient echo/spin echo (GESE) sequence has been used to measure T2 and T2* simultaneously in the brain at 7T in both healthy volunteers and patients . GESE is particularly useful at 7T as it is insensitive to RF pulse errors since errors in either of the pulse flip angles will cause constant attenuation of all the echoes, leading to a simple reduction in SNR, and it has a low SAR....

متن کامل

Diffusion Weighted Imaging at 7T with STEAM-EPI and GRAPPA

Introduction: Diffusion Imaging at 7 Tesla has been quite a challenge. Standard diffusion sequences require long time to play diffusion gradients, especially for high b-values. This compromises higher intrinsic SNR [1]at 7T with shorter T2 relaxation. At 7T twice refocused spin echo [2] used for standard diffusion weighted imaging also suffers from high SAR. Magnetic field inhomogeneities that ...

متن کامل

Retinotopic mapping with spin echo BOLD at 7T.

For blood oxygenation level-dependent (BOLD) functional MRI experiments, contrast-to-noise ratio (CNR) increases with increasing field strength for both gradient echo (GE) and spin echo (SE) BOLD techniques. However, susceptibility artifacts and nonuniform coil sensitivity profiles complicate large field-of-view fMRI experiments (e.g., experiments covering multiple visual areas instead of focus...

متن کامل

Evaluation of Sensory Pathways in Spinal Cord by Comparison of fMRI Methodologies

Introduction: Today, clinicians and neuroscientists need to have a comprehensive survey of neurological pathologies and injuries. For the First-time, SEEP contrast and Spin-Echo pulse sequences was used for functional imaging of the Lumbar spinal cord. This method used by several research groups for Spinal cord mapping, but other researchers tried to improve BOLD fMRI to Spina...

متن کامل

A Multi-Resolution Comparison of Single-Shot EPI, 3DFFE and PRESTO for fMRI at 7T

INTRODUCTION Single-shot Echo-Planar Imaging (EPI) is the sequence most commonly used for fMRI experiments. At high field, e.g. 7T, magnetic field inhomogeneities cause spins to become out of phase quickly, and distortion and signal dropout become severe [1]. Consequently, single-shot EPI fMRI suffers technical limitations at high field. Here we consider two alternatives to EPI for high field f...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008