Delivery of salbutamol to nonventilated preterm infants by metered-dose inhaler, jet nebulizer, and ultrasonic nebulizer.

نویسندگان

  • T F Fok
  • K Lam
  • P C Ng
  • T F Leung
  • H K So
  • K L Cheung
  • W Wong
چکیده

To identify the most efficient device for the delivery of bronchodilator aerosol to nonventilated preterm infants with chronic lung disease, we compared the metered dose inhaler (MDI) used in conjunction with a non-valved spacer, an ultrasonic nebulizer with a small medication cup, and two jet nebulizers. The subjects were enrolled in two double-blind randomized crossover studies. In study A (n=10), each infant was given a nominal dose of 200 microg of salbutamol by a MDI (Ventolin) at 4 h intervals, and in random sequence via an Aerochamber (Neonatal Aerochamber) with its one-way valve removed, an ultrasonic nebulizer with a small cone-shaped medication cup (Siemens Electronics), and a jet nebulizer (Side-stream). Their functional residual capacity (FRC) and static respiratory system mechanics were measured before, and at 15, 30, 60, and 120 min after aerosol delivery. Study B (n=10) was carried out in an identical manner, but with a different jet nebulizer (Hudson). In both studies, administration of salbutamol aerosol via the MDI Aerochamber or ultrasonic nebulizer resulted in a significantly greater reduction in respiratory system resistance than via jet nebulizers. Furthermore, the use of MDI Aerochamber or ultrasonic nebulizer was associated with a greater degree of post-treatment tachycardia and improvement in FRC. The bronchodilating effect of salbutamol delivered via the ultrasonic nebulizer appeared to be slightly greater than that via the MDI-Aerochamber, receiving significance only in Study B. We conclude that both the metered-dose inhaler used with a nonvalved Aerochamber and the ultrasonic nebulizer with a small medication cup are both more efficient than the jet nebulizers in preterm infants.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Vibrating membrane devices deliver aerosols more efficient than standard devices: a study in a neonatal upper airway model.

BACKGROUND Aerosol therapy in preterm infants is challenging, as a very small proportion of the drug deposits in the lungs. AIM Our aim was to compare efficiency of standard devices with newer, more efficient aerosol delivery devices. METHODS Using salbutamol as a drug marker, we studied two prototypes of the investigational eFlow(®) nebulizer for babies (PARI Pharma GmbH), a jet nebulizer ...

متن کامل

A comparison of responses to albuterol delivered by two aerosol devices.

Nineteen outpatients with stable obstructive pulmonary disease (mean forced expiratory volume in one second [FEV1], 1.00 + 0.10 L) were evaluated for airway response to albuterol (salbutamol) administered by metered-dose inhaler and Bosch ultrasonic nebulizer (BUSN). Albuterol administered by metered-dose inhaler but not by nebulizer caused a significant increase in FEV1 and the mean forced exp...

متن کامل

[Metered-dose inhalers with home-made spacers versus nebulizers to treat moderate wheezing attacks in children].

OBJECTIVE To compare the effectiveness of salbutamol administration by metered-dose inhaler with a home-made spacer versus jet nebulizer in children with moderate wheezing attacks. MATERIAL AND METHODS A randomized, single-blinded trial was performed with a convenience sample of children presenting wheezing. The children were enrolled in an emergency room and randomly assigned to one of two t...

متن کامل

Randomised crossover trial of salbutamol aerosol delivered by metered dose inhaler, jet nebuliser, and ultrasonic nebuliser in chronic lung disease.

AIMS To compare the efficacy of salbutamol delivered by metered dose inhaler (MDI), jet nebuliser, and ultrasonic nebuliser in ventilated infants with chronic lung disease. METHODS Twenty preterm ventilated infants with chronic lung disease were enrolled in two studies. In study 1 (n = 10), each infant was given 200 micrograms of salbutamol at 4 hour intervals and in random sequence from a me...

متن کامل

Comparative efficacy of jet nebulizer and metered dose inhaler with spacer device in the treatment of acute asthma.

OBJECTIVE To compare the relative efficacy of jet nebulizer and metered dose inhaler (MDI) with spacer for the administration of aerosolized salbutamol in an acute exacerbation of bronchial asthma. DESIGN Randomized prospective study. SETTING Emergency Room. METHODS In 60 subjects with acute asthma aged between 1 to 12 years, clinical and laboratory assessment of severity at recruitment i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The European respiratory journal

دوره 12 1  شماره 

صفحات  -

تاریخ انتشار 1998