Predicted versus measured thoracic gas volumes of collegiate athletes made by the BOD POD air displacement plethysmography system.

نویسنده

  • Dale R Wagner
چکیده

Measured (TGVm) and predicted (TGVp) thoracic gas volumes from the BOD POD were compared in 33 lean, university athletes. On average, TGVp (3.529 L) was not significantly different (p = 0.343) from TGVm (3.628 L); however, there was a bias (r = -0.703, p < 0.001). The difference in the percentage of body fat (BF) was within ±2% BF for 76% of the sample, but athletes at the extremes of height should have TGV measured.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment and prediction of thoracic gas volume in pregnant women: an evaluation in relation to body composition assessment using air displacement plethysmography.

Assessment of body fat (BF) in pregnant women is important when investigating the relationship between maternal nutrition and offspring health. Convenient and accurate body composition methods applicable during pregnancy are therefore needed. Air displacement plethysmography, as applied in Bod Pod, represents such a method since it can assess body volume (BV) which, in combination with body wei...

متن کامل

Body composition by air-displacement plethysmography by using predicted and measured thoracic gas volumes.

The BOD POD, a new air-displacement plethysmograph for measuring human body composition, utilizes the inverse relationship between pressure and volume (Boyle's law) to measure body volume directly. The quantity of air in the lungs during tidal breathing, the average thoracic gas volume (Vtg), is also measured by the BOD POD by using a standard plethysmographic technique. Alternatively, the BOD ...

متن کامل

Air Displacement Plethysmography versus Dual-Energy X-Ray Absorptiometry in Underweight, Normal-Weight, and Overweight/Obese Individuals

BACKGROUND Accurately estimating fat percentage is important for assessing health and determining treatment course. Methods of estimating body composition such as hydrostatic weighing or dual-energy x-ray absorptiometry (DXA), however, can be expensive, require extensive operator training, and, in the case of hydrostatic weighing, be highly burdensome for patients. Our objective was to evaluate...

متن کامل

Subject Positioning in the BOD POD® Only Marginally Affects Measurement of Body Volume and Estimation of Percent Body Fat in Young Adult Men

INTRODUCTION The aim of the study was to evaluate whether subject positioning would affect the measurement of raw body volume, thoracic gas volume, corrected body volume and the resulting percent body fat as assessed by air displacement plethysmography (ADP). METHODS Twenty-five young adult men (20.7±1.1 y, BMI = 22.5±1.4 kg/m(2)) were measured using the BOD POD® system using a measured thora...

متن کامل

Assessment of body composition by air-displacement plethysmography: influence of body temperature and moisture

BACKGROUND: To investigate the effect of body temperature and moisture on body fat (%fat), volume and density by air-displacement plethysmography (BOD POD). METHODS: %fat, body volume and density by the BOD POD before (BOD PODBH) and immediately following hydrostatic weighing (BOD PODFH) were performed in 32 healthy females (age (yr) 33 +/- 11, weight (kg) 64 +/- 14, height (cm) 167 +/- 7). Bod...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Applied physiology, nutrition, and metabolism = Physiologie appliquee, nutrition et metabolisme

دوره 40 10  شماره 

صفحات  -