Detection of PCR inhibitors in cervical specimens by using the AMPLICOR Chlamydia trachomatis assay.

نویسندگان

  • R P Verkooyen
  • A Luijendijk
  • W M Huisman
  • W H Goessens
  • J A Kluytmans
  • J H van Rijsoort-Vos
  • H A Verbrugh
چکیده

To determine that susceptibility of AMPLICOR Chlamydia trachomatis PCR to inhibitory factors possibly present in cervical specimens, we obtained cervical specimens from 200 gynecology patients attending our outpatient clinic. The prevalence of C. trachomatis infection was 4.1%, as determined by cell culture. All AMPLICOR specimens were tested in one procedure as described by the manufacturer, and after the specimen was spiked with C. trachomatis, several other pretreatment protocols were used. Complete inhibition of the PCR was observed in 38 (19%) cervical specimens. Heat treatment at 95 degrees C, freeze-thawing, or 10-fold dilution of the samples reduced the initial inhibition to 9, 16, or 9%, respectively. A combination of heat treatment and 10-fold dilution reduced the inhibition to 4% of the samples. A second specimen type (swabs inoculated in 0.2 M sucrose phosphate buffer [2SP]) was also evaluated. A 10-fold dilution of the spiked 2SP specimen resulted in an inhibition rate of 6%, which was comparable to that obtained by centrifugation of the 2SP specimen prior to processing. Furthermore, it was shown that the inhibition was not correlated with blood contamination. Processing the specimens on the day of collection or the day after resulted in a higher inhibition rate than did delayed processing (27.6 versus 15.5%, respectively). An inverse correlation was found between the concentration of C. trachomatis added to the sample and the rate of inhibition observed. The inhibition was partly correlated with the pH of the cervical mucosa. Decreased inhibition was found at pH values of > or = 7.5. The effects of blood, pH, and delay in processing were all evaluated by using the AMPLICOR specimen. We conclude that the susceptibility of AMPLICOR C. trachomatis PCR to inhibiting factors in cervical specimens can be significantly reduced if the pretreatment procedure includes heat treatment or the use of 2SP transport medium. Also, a 10-fold dilution of the clinical specimen followed by heat treatment will largely prevent the inhibition of this PCR.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Detection of Chlamydia trachomatis infections in women by Amplicor PCR: comparison of diagnostic performance with urine and cervical specimens.

We used the Roche Amplicor PCR assay to compare urine and cervical swabs as sample material in the detection of Chlamydia trachomatis causing genital infections. The diagnostic performance of Amplicor PCR was compared with that of cell culture and the Gen-Probe PACE 2 assay with cervical specimens. If discrepant from other results, the specimens negative by PCR were diluted and reanalyzed to re...

متن کامل

Combined cervical swab and urine specimens for PCR diagnosis of genital Chlamydia trachomatis infection.

OBJECTIVES Sampling of both the cervix and urine increases the chance of detection of Chlamydia trachomatis compared with sampling either site alone. We determined the effect of combining urine and cervical swab specimens in the clinic setting on the sensitivity of C trachomatis polymerase chain reaction (PCR) testing. METHODS For each of 100 women attending a genitourinary medicine clinic wi...

متن کامل

Preparation and validation of PCR-generated positive controls for diagnostic dot blotting.

References 1. Loeffelholz MJ, Lewinski CA, Silver SR, Purohit AP, Herman SA, Buonagurio DA, Dragon EA. Detection of Chlamydia trachomatis in endocervical specimens by polymerase chain reaction. J Clin Microbiol 1992;30:2847–51. 2. Bass CA, Jungkind DL, Silverman NS, Bondi JM. Clinical evaluation of a new polymerase chain reaction assay for detection of Chlamydia trachomatis in endocervical spec...

متن کامل

Polymerase Chain Reaction Assay With Urine Specimens in the Diagnosis of Acute Chlamydia trachomatis Infection in Women

OBJECTIVE The purpose of this study was to evaluate the benefits achievable by Amplicor polymerase chain reaction (PCR) (F. Hoffmann-LaRoche Ltd., Basel, Switzerland) with urine specimens in addition to PACE 2 (Gen-Probe, Inc., San Diego, California) assay with cervical swab specimens in the diagnosis of Chlamydia trachomatis in women. METHODS Cervical and urine specimens from 286 women were ...

متن کامل

Validation of roche COBAS Amplicor assay for detection of Chlamydia trachomatis in rectal and pharyngeal specimens by an omp1 PCR assay.

Screening guidelines for men who have sex with men (MSM) recommend testing of extragenital sites (pharyngeal and rectal) for gonorrhoea and chlamydia. Testing of specimens from these sites is not validated by most commercial nucleic amplification tests, such as the COBAS Amplicor assay. To investigate the utility of the COBAS Amplicor assay for detection of Chlamydia trachomatis in extragenital...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 34 12  شماره 

صفحات  -

تاریخ انتشار 1996