On Pump Coronary Artery Bypass Graft Surgery Versus Off Pump Coronary Artery Bypass Graft Surgery: A Review
نویسندگان
چکیده
There are two basic ways of performing coronary artery bypass graft surgery (CABG): on pump CABG and off pump CABG. Off pump CABG is relatively a newer procedure to on-pump CABG and does not require the use of the cardiopulmonary bypass machine. On pump CABG is the more traditional method of performing bypass surgery. However its resultant inflammatory effects cause renal dysfunction, gastrointestinal distress and cardiac abnormalities which have forced the surgeons to look for alternatives to the procedure. An extensive literature search revealed that on pump CABG causes better revascularization as compared to off pump CABG while off pump CABG has a much lower post operative morbidity and mortality especially in high risk patients. We suggest that the technique used should depend on the ease of the surgeon doing the operation as both the methods seem almost equally efficient according to the review.
منابع مشابه
Off-Pump Versus On-Pump Coronary Artery Bypass Graft Surgery, prospective cohort study
Introduction: Coronary artery bypass grafting is a surgical operation that bypasses atherosclerotic coronary vessels and restores blood flow to the ischemic zone of hearts. And two different conventional methods are ON-pump CABG, and Off-pump CABG. Altogether, the efficacy and safety of these two types of surgical procedures are still under debate. In this study, we aim to com...
متن کاملEmergency Conversion from Off Pump to Cardiopulmonary Bypass in Patients with Coronary Artery Bypass Graft Surgery
Introduction: As off pump Coronary artery bypass grafting surgery (CABG) is a developing method in coronary cardiac surgery, most surgeons are anxious about the danger of emergency crash conversion. In this observational study we tried to show the rate and outcome of conversion . Material and methods: In this descriptive study about 477 coronary off-pump CABG patients were operated in Ghaem hos...
متن کاملComparison of Unstable Hemodynamic Patients Undergoing Coronary Artery Bypass Graft Surgery with on- or off-Pump Methods
Introduction: Coronary artery disease (CAD) is the most common type of heart disease, with a mortality rate of 385,000 person per year in the United States. There are two main methods for CAD treatments: angioplasty and bypass surgery. Coronary Artery Bypass Grafting (CABG) is one of the greatest surgical operations of the 20th century and it is presented as most effective and long-term therapi...
متن کاملComparison of Treatment Outcomes in Off-pump Coronary Artery Bypass Graft and Medical Therapy in Patients with Triple-vessel Coronary Artery Disease and Severe Ventricular Dysfunction
Introduction: Heart failure is a major hazard for public health. Despite recent advance in medical therapy, there is not enough information on the outcome of off-pump coronary artery bypass (OPCAB) and medical therapy on the patients with severe ventricular dysfunction and triple-vessel (CAD). This study aimed to compare treatment outcomes and mortality rate in patients undergoing off-pump coro...
متن کاملSerum lactate as a prognostic factor in coronary artery bypass graft operation by on pump method
Background: Lactic acidosis in cardiac surgical patients is a manifestation of systemic inflammation and excess pro-inflammatory cytokine production. This investigation was designed to integrate basic concepts about lactate acidosis with a clinically used of serum lactate in patients under coronary artery bypass surgery (CABG) by on pump method. Methods: From August to September 2012, 15 patie...
متن کاملEvaluation of Factors Influencing Liver Function Test in On-Pump Coronary Artery Bypass Graft Surgery
Background: Liver dysfunction during on-pump coronary artery bypass graft surgery (CABG) is a rare complication but is associated with significant morbidity and mortality. The ability to identify high-risk patients may be helpful in planning appropriate management strategies. We aimed to evaluate the factors influencing liver function tests during on-pump CABG.Methods: In 146 patients scheduled...
متن کامل