Estimation of local anisotropy of plexiform bone: Comparison between depth sensing micro-indentation and Reference Point Indentation.
نویسندگان
چکیده
The recently developed Reference Point Indentation (RPI) allows the measurements of bone properties at the tissue level in vivo. The goal of this study was to compare the local anisotropic behaviour of bovine plexiform bone measured with depth sensing micro-indentation tests and with RPI. Fifteen plexiform bone specimens were extracted from a bovine femur and polished down to 0.05µm alumina paste for indentations along the axial, radial and circumferential directions (N=5 per group). Twenty-four micro-indentations (2.5µm in depth, 10% of them were excluded for testing problems) and four RPI-indentations (~50µm in depth) were performed on each sample. The local indentation modulus Eind was found to be highest for the axial direction (24.3±2.5GPa) compared to the one for the circumferential indentations (19% less stiff) and for the radial direction (30% less stiff). RPI measurements were also found to be dependent on indentation direction (p<0.001) with the exception of the Indentation Distance Increase (IDI) (p=0.173). In particular, the unloading slope US1 followed similar trends compared to the Eind: 0.47±0.03N/µm for axial, 11% lower for circumferential and 17% lower for radial. Significant correlations were found between US1 and Eind (p=0.001; R(2)=0.58), while no significant relationship was found between IDI and any of the micro-indentation measurements (p>0.157). In conclusion some of the RPI measurements can provide information about local anisotropy but IDI cannot. Moreover, there is a linear relationship between most local mechanical properties measured with RPI and with micro-indentations, but IDI does not correlate with any micro-indentation measurements.
منابع مشابه
Investigation of Ultrastructural and Mechanical Properties of Rat Cortical Bone Using Micro-ct, Three- Point Bending Testing, and the Reference Point Indentation Technique By
متن کامل
Reference Point Indentation of Human Trabecular Bone Treated with Bisphosphonates for Varying Durations
OF THESIS REFERENCE POINT INDENTATION OF HUMAN TRABECULAR BONE TREATED WITH BISPHOSPHONATES FOR VARYING DURATIONS Reference point indentation (RPI), a novel form of micro-indentation, quantifies RPI material parameters which correlate with modulus, yield stress, strength, or toughness. Information linking bisphosphonate treatment length with the material properties of osteoporotic trabecular bo...
متن کاملPrediction of viscoelastic and plastic properties of polymers using indentation
Indentation methodologies are gaining popularity as they provide means of local property estimation, utilize smaller sample sizes, and do not destroy specimens. Classically, indentation has been used to measure hardness and Young’s modulus [1], but researchers have also proposed ways of predicting stress–strain curves [2], yield strength [3], and fracture toughness [3]. Different indentation te...
متن کاملA novel optical coherence tomography-based micro-indentation technique for mechanical characterization of hydrogels.
Depth-sensing micro-indentation has been well recognized as a powerful tool for characterizing mechanical properties of solid materials due to its non-destructive approach. Based on the depth-sensing principle, we have developed a new indentation method combined with a high-resolution imaging technique, optical coherence tomography, which can accurately measure the deformation of hydrogels unde...
متن کاملReference point indentation is not indicative of whole mouse bone measures of stress intensity fracture toughness
Bone fragility is a concern for aged and diseased bone. Measuring bone toughness and understanding fracture properties of the bone are critical for predicting fracture risk associated with age and disease and for preclinical testing of therapies. A reference point indentation technique (BioDent) has recently been developed to determine bone's resistance to fracture in a minimally invasive way b...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of biomechanics
دوره 48 15 شماره
صفحات -
تاریخ انتشار 2015