Temporal coherence and spectral linewidth of an injection-seeded transient collisional soft x-ray laser.

نویسندگان

  • L M Meng
  • D Alessi
  • O Guilbaud
  • Y Wang
  • M Berrill
  • B M Luther
  • S R Domingue
  • D H Martz
  • D Joyeux
  • S De Rossi
  • J J Rocca
  • A Klisnick
چکیده

The temporal coherence of an injection-seeded transient 18.9 nm molybdenum soft x-ray laser was measured using a wavefront division interferometer and compared to model simulations. The seeded laser is found to have a coherence time similar to that of the unseeded amplifier, ~1 ps, but a significantly larger degree of temporal coherence. The measured coherence time for the unseeded amplifier is only a small fraction of the pulsewidth, while in the case of the seeded laser it approaches full temporal coherence. The measurements confirm that the bandwidth of the solid target amplifiers is significantly wider than that of soft x-ray lasers that use gaseous targets, an advantage for the development of sub-picosecond soft x-ray lasers.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

High-brightness injection-seeded soft-x-ray-laser amplifier using a solid target.

We demonstrate the generation of an intense soft-x-ray-laser beam by saturated amplification of high harmonic seed pulses in a dense transient collisional soft-x-ray-laser plasma amplifier created by heating a titanium target. Amplification in the 32.6 nm line of Ne-like Ti generates laser pulses of subpicosecond duration that are measured to approach full spatial coherence. The peak spectral b...

متن کامل

Single-shot soft x-ray laser linewidth measurement using a grating interferometer.

The linewidth of a 14.7 nm wavelength Ni-like Pd soft x-ray laser was measured in a single shot using a soft x-ray diffraction grating interferometer. The instrument uses the time delay introduced by the gratings across the beam to measure the temporal coherence. The spectral linewidth of the 4d1S0-4p1P1 Ni-like Pd lasing line was measured to be Δλ/λ=3×10(-5) from the Fourier transform of the f...

متن کامل

Spatial coherence measurements of a 13.2 nm transient nickel-like cadmium soft x-ray laser pumped at grazing incidence.

The spatial coherence of a 13.2 nm transient collisional Ni-like Cd soft X-ray laser pumped at 23 degrees grazing incidence was measured in a series of Young's double-slit experiments. We observed pronounced fringe visibility variations associated with microstructures in the beam's intensity profile. The transverse coherence length was measured to be about 1/20 of the beam diameter and did not ...

متن کامل

Longitudinal coherence measurements of a transient collisional x-ray laser.

We present what is to our knowledge the first longitudinal coherence measurement of a transient inversion collisional x-ray laser. We investigated the picosecond output of a Ni-like Pd x-ray laser at 14.68 nm generated by the COMET laser facility at the Lawrence Livermore National Laboratory. Interference fringes were generated with a Michelson interferometer setup in which a thin multilayer me...

متن کامل

Highly coherent injection-seeded 13.2 nm tabletop soft x-ray laser.

We report a dramatic improvement of the spatial coherence and beam divergence (0.66 mrad) of a 13.2 nm wavelength Ni-like Cd tabletop laser by injection seeding the soft x-ray laser amplifier with high-harmonics pulses generated in a Ne gas jet. This phase coherent laser is an attractive light source for at-wavelength interferometry of extreme ultraviolet lithography optics and other applications.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Optics express

دوره 19 13  شماره 

صفحات  -

تاریخ انتشار 2011