Radiation exposure benefit of a lead cap in invasive cardiology.
نویسندگان
چکیده
BACKGROUND Occupational head exposure to radiation in cardiologists may cause radiation induced cataracts and an increased risk of brain cancer. OBJECTIVE To determine the effectiveness of 0.5 mm lead equivalent caps, not previously used in invasive cardiology, in comparison with a 1.0 mm lead equivalent ceiling mounted lead glass screen. DESIGN An anthropomorphic Alderson-Rando phantom was used to represent the patient. Scatter entrance skin air kerma to the operator position (S-ESAK-O) was measured during fluoroscopy for all standard angulations and the S-ESAK-O per dose-area product (DAP) calculated, as applied to the phantom. RESULTS Measured mean (SD) left/right anterior oblique angulation ratios of S-ESAK-O without lead devices were 23.1 (10.1), and varied as a function of tube angulation, body height, and angle of incidence. S-ESAK-O/DAP decreased with incremental operator body height by 10 (3)% per 10 cm. A 1.0 mm lead glass shield reduced mean S-ESAK-O/DAP originating from coronary angiography from 1089 (764) to 54 (29) nSv/Gy x cm2. A 0.5 mm lead cap was effective in lowering measured levels to 1.8 (1.1) nSv/Gy x cm2. Both devices together enabled attenuation to 0.5 (0.1) nSv/Gy x cm2. The most advantageous line of vision for protection of the operator's eyes was > or = 60 degrees rightward. CONCLUSIONS Use of 0.5 mm lead caps proved highly effective, attenuating S-ESAK-O to 2.7 (2.0) x 10(-3) of baseline, and to 1.2 (1.4) x 10(-3) of baseline where there was an additional 1.0 mm lead glass shield. These results could vary according to the x ray systems used, catheterisation protocols, and correct use of radiation protection devices.
منابع مشابه
Are Radiation Exposure Levels Used in Cardiology Dangerous?
Background: The number of interventional cardiology procedures performed has increased rapidly over the past years. While these procedures help physicians avoid using highly complicated invasive methods, it usually leads to high levels of exposure to ionizing radiation of both patients and cardiologist. The dose received by the cardiologist during interventional cardiology procedures is determi...
متن کاملINTERVENTIONAL CARDIOLOGY AND SURGERY Radiation exposure benefit of a lead cap in invasive cardiology
Background: Occupational head exposure to radiation in cardiologists may cause radiation induced cataracts and an increased risk of brain cancer. Objective: To determine the effectiveness of 0.5 mm lead equivalent caps, not previously used in invasive cardiology, in comparison with a 1.0 mm lead equivalent ceiling mounted lead glass screen. Design: An anthropomorphic Alderson-Rando phantom was ...
متن کاملEffectiveness of a lead cap in radiation protection of the head in the cardiac catheterisation laboratory.
Introduction During the past 30 years, interventional cardiology has advanced dramatically resulting in outstanding increases in occupational radiation exposure of interventional cardiologists. Despite the remarkable changes in fluoroscopic procedures, radiation protection technology is not much different from how it was decades ago. Moreover, new evidence on occupational radiation suggests tha...
متن کاملRemarkable reduction of exposure rate in patients with stress-only myocardial perfusion scan: Let’s safe mankind from unjustified radiation exposure
Introduction: To measure radiation exposures rate in low-risk patients having stress-only and stress-rest myocardial perfusion imaging. Methods: This was a prospective study conducted from January 2012 till November 2012 upon patients with low pre-test probability for coronary artery disease (CAD). A stress MPI (stress-only if MPI is normal and no resting study) followed by a resting MPI study...
متن کاملLead pig for use with screw cap vials.
UNLABELLED A lead pig specifically designed for use with solid screw cap vials is described. METHODS The salient features of this design include a compressible polyethylene sleeve, which is housed in the lower section of the pig, and a partially recessed O-ring, which is housed in the upper section of the pig. These features permit both the vial and the cap to be secured independently without...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Heart
دوره 89 10 شماره
صفحات -
تاریخ انتشار 2003