Initial stability of type-2 tibial defect treatments.

نویسندگان

  • B Frehill
  • A Crocombe
  • S Cirovic
  • Y Agarwal
  • N Bradley
چکیده

Treatment of proximal tibial defects is important to the survival of tibial prosthesis after total knee replacement. The objective of this finite element study was to determine a better understanding of the stresses produced by different treatment options for moderate uncontained type-2 defects. Methods analysed were the use of metal wedges, metal blocks, cement wedges, and cement blocks for the two defect angles 15 degrees and 30 degrees. The effect of a stem extension on the stress profiles was also analysed for each defect treatment and angle to establish the necessity of these extensions and consequent bone removal on the stability of the augments. Equivalent stresses in two regions of interest (ROIs) adjacent to the augments and shear stresses along the bone-cement interface of the defect were investigated. The lowest equivalent stresses were found in the metal block augment for both defect angles and ROIs. The highest equivalent stress in the ROIs and shear stress values along the bone-cement interface of the defect were found in the cement wedge augment model for both defect angles. Stem extensions were shown to increase equivalent stresses in the bone closer to the tibial stem but to decrease equivalent stresses closer to the cortical bone. The use of a stem extension significantly increased the shear stresses in the cement in all cases except in the metal block model. It is recommended that metal block augments are used without a stem extension in small-defect (i.e. peripheral defect angle of 15 degrees) total knee replacement procedures.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Epithelialization Over a Scaffold of Antibiotic-Impregnated PMMA Beads: A Salvage Technique for Open Tibial Fractures with Bone and Soft Tissue Loss When all Else Fails

  The management of soft tissue defects in tibial fractures is essential for limb preservation. Current techniques are not without complications and may lead to poor functional outcomes. A salvage method is described using three illustrative cases whereby a combination of flaps and antibiotic-impregnated polymethylmethacrylate beads are employed to fill the bony defect, fight the infection, and...

متن کامل

Functional Outcome and Incidence of Osteoarthritis in Operated Tibial Plateau Fractures

Background: In the challenging tibial condyle fractures despite anatomical joint reconstruction, development ofosteoarthritis may still occur secondary to the initial articular cartilage and meniscal injury. The aim of the study wasto know incidence of osteoarthritis in our operated cases of tibial plateau fracture and to evaluate functional outcome.Methods: Our operated 60 patients of tibial p...

متن کامل

APPROACH TO MEDIAL TIBIAL DEFECT IN TKA THE INFLUENCE OF DEFECT AREA ?

This was Presented in 5th International Congress of Iranian Iranian Society of Knee Surgery, Arthroscopy, and Sports Traumatology (ISKAST), 14-17 Feb 2018- Kish, Iran

متن کامل

A Comparative Biomechanical Analysis

J Bone Joint Surg [Br] 2009;91-B:271-7. Received 16 June 2008; Accepted after revision 26 September 2008 The treatment of bony defects of the tibia at the time of revision total knee replacement is controversial. The place of compacted morsellised bone graft is becoming established, particularly in contained defects. It has previously been shown that the initial stability of impaction-grafted t...

متن کامل

Tibial revision knee arthroplasty with metaphyseal sleeves: The effect of stems on implant fixation and bone flexibility

INTRODUCTION Revision total knee arthoplasty often requires modular implants to treat bone defects of varying severity. In some cases, it may not be clear which module size and implant combination (e.g. sleeve and stem) should be chosen for a specific defect. When balancing implant stability and osseointegration against stress-shielding, it is important to choose an appropriate implant combinat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine

دوره 224 1  شماره 

صفحات  -

تاریخ انتشار 2010