AIMS Transradial catheterization (TRC) is a dominant access site for coronary catheterization and percutaneous coronary interventions (PCI) in many centers. Previous studies reported higher intimal thickness of the radial artery (RA) wall in patients with a previous history of TRC. In this investigation the aim was to assess the intimal changes of RA using the optical coherence tomography (OCT) intravascular imaging in a serial manner. METHODS AND RESULTS 100 patients with the diagnosis of non-ST-elevation myocardial infarction (nSTEMI) treated by PCI were enrolled (6 patients were excluded from this analysis because of occluded RA at follow-up [2 patients] and insufficient quality of OCT images [4 patients]). An 54mm long OCT run of the RA was performed immediately after the index PCI and repeated 9 months later. Volumetric analyses of the intimal layer and lumen changes were conducted. Median intimal volume at baseline versus 9 months was 33.9mm3 (19.0; 69.4) versus 39.0mm3 (21.7; 72.6) (p<0.001); and median arterial lumen volume was 356.3mm3 (227.8; 645.3) versus 304.7mm3 (186.1; 582.7) (p<0.001). There was no significant difference in the effect of any clinical factor on the RA volume changes. CONCLUSIONS OCT volumetric analyses at baseline and 9 months showed a significant increase in the radial artery intimal layer volume and a decrease in lumen volume after transradial PCI. No significant factors affecting this process were identified.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A New 3-D Automated Computational Method to Evaluate In-Stent Neointimal Hyperplasia in In-Vivo Intravascular Optical Coherence Tomography Pullbacks

Detection of stent struts imaged in vivo by optical coherence tomography (OCT) after percutaneous coronary interventions (PCI) and quantification of in-stent neointimal hyperplasia (NIH) are important. In this paper, we present a new computational method to facilitate the physician in this endeavor to assess and compare new (drug-eluting) stents. We developed a new algorithm for stent strut det...

متن کامل

Assessment of acute injuries and chronic intimal thickening of the radial artery after transradial coronary intervention by optical coherence tomography.

AIMS Transradial coronary intervention (TRI) introduces a trauma to the radial artery (RA), possibly influencing quality as a bypass conduit if subsequently used. We sought to determine the acute and chronic effects of TRI on the RA by optical coherence tomography (OCT). METHODS AND RESULTS Immediately after TRI completion, 73 RAs in 69 patients were examined. The sheath was pulled back 2 cm ...

متن کامل

Serial Changes of Neointimal Tissue after Everolimus-Eluting Stent Implantation in Porcine Coronary Artery: An Optical Coherence Tomography Analysis

PURPOSES The serial changes in neointimal tissues were compared between everolimus-eluting stent (EES) and bare-metal stent (BMS) in the porcine coronary artery using optical coherence tomography (OCT). METHODS Serial (1, 3, and 6 month follow-up after stent implantation) OCT examinations were performed in 15 swine with 15 BMS- and 15 EES-treated lesions in porcine coronary arteries. RESULT...

متن کامل

In Vivo Demonstration of Frail Neointimal Tissue Embolization After Angioplasty With a Drug-Coated Balloon Confirmed by Optical Coherence Tomography and Histology.

A 60-year-old woman experienced exertional chest pain. She underwent percutaneous coronary intervention with a drug-eluting stent (Nobori, Terumo Corporation, Tokyo) at the midportion of the left anterior descending artery. In the 3-month follow-up angiography, there was an in-stent restenosis at the midportion of the left anterior descending artery, which was also the site of a previous stent ...

متن کامل

The relationship between post-stent strut apposition and follow-up strut coverage assessed by a contour plot optical coherence tomography analysis.

OBJECTIVES This study sought to evaluate the relationship between post-stent strut apposition and follow-up strut coverage using contour plot optical coherence tomographic analysis. BACKGROUND Tracking the fate of interested regions of struts at different time points has not been investigated. METHODS Post-intervention and 6-month follow-up optical coherence tomographic evaluations were per...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2017