[Evaluation of strategies aimed at reducing the level of noise in different areas of neonatal care in a tertiary hospital].

نویسندگان

  • Adriana Nieto-Sanjuanero
  • José Quero-Jiménez
  • Daniel Cantú-Moreno
  • Isaías Rodríguez-Balderrama
  • Fernando Montes-Tapia
  • Nadina Rubio-Pérez
  • Consuelo Treviño-Garza
  • Manuel de la O-Cavazos
چکیده

OBJECTIVE To determine the noise levels of different areas responsible for newborn care, develop intervention strategies to decrease the noise, and evaluate its effectiveness. METHODS Prospective, observational and longitudinal study carried out using a sonometer, measuring sound levels for three weeks in the neonatal intensive care unit (NICU), neonatal intermediate care unit (UCIREN), delivery (TOCO QX) and nursery (CUNERO) units. We implemented an intervention program and subsequent measurements were performed under the same initial conditions. RESULTS When comparing the decibel levels in different areas during the three weeks, pre- and post-intervention, we found at the neonatal intensive care unit 59.9±4.8 vs. 56.4±4.7 dB (p<0.001), neonatal intermediate care unit 55.3±3.9 vs. 51.3±4.4 dB (p<0.001), delivery unit 57.3±4.6 vs. 57.3±5.5 dB (NS), and nursery unit 57.6±5.8 vs. 53.9±5.8 dB (p<0.001). CONCLUSIONS There was a significant reduction in noise levels of 3.5 dB at the NICU, 4 dB at UCIREN and 3.7 dB at TOCO QX, so the intervention program was effective in these areas; however, the decibel levels registered continue above those recommended by international standards.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of Noise Level and Its Sources in the Neonatal Intensive Care Unit and Neonatal Ward

Background: In Neonatal intensive care units (NICU) different sound intensities and frequencies are produced from different sources, which may exert undesirable physiological effects on the infants. The aim of this study was to determine the noise level and its sources in the NICU and neonatal ward of Al-Zahra Hospital of Rasht, Iran. Methods: In this descriptive cross-sectional study, the inte...

متن کامل

Neonatal Thrombosis: Incidence and Risk Factors in a Tertiary Care Hospital in Iran

Background: Neonatal thrombosis is one of the most important challenges among patients admitted in Neonatal Intensive Care Unit (NICU), which can lead to an asymptomatic condition, limb loss or even death. This study was performed to determine the incidence and risk factors of neonatal thrombosis in a tertiary care hospital in Tehran, Iran. Material and Methods: In this historical cohort, all n...

متن کامل

Identification and Evaluation of Human Errors in Nurses in Different Wards of Yazd Madar Hospital Before and After Proposed Control Strategies Using SHERPA Method in 2019

Background: Despite widespread efforts to reduce human error in different occupations, unsafe practices and behaviors are still the main cause of many accidents. The occurrence of medical errors in health care systems as one of the most important factors in decreasing the quality of services in this field has received much attention in recent years. Therefore, this study aimed to identify and ...

متن کامل

Investigation of environmental stimuli in the neonatal intensive care unit of Ghaem Hospital in Mashhad

Introduction[N1] :One of these annoying stimuli and a major source of stress in the NICU is sound. In neonatal intensive care units, sounds with different intensities and frequencies are produced from different sources such as fan devices, intermittent alarms, ventilators, telephones, door opening and closing, and staff conversations; Studies have reported that the average noise level in the NI...

متن کامل

The Association between Noise Annoyance and General Health among Iranian Nurses at Tabriz Pediatric Hospital

Background: This study aimed to measure the sound level and assess the association between noise annoyance and general health in Iranian nurses at Tabriz Pediatric Hospital in neonatal, infectious, internal, NICU, and emergency care wards. Materials and Methods: The noise level was measured continuously according to ISO9612. The general health questionnaire-28, the noise annoyance scale based ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Gaceta medica de Mexico

دوره 151 6  شماره 

صفحات  -

تاریخ انتشار 2015