Wavefront-guided custom ablation for myopia using the NIDEK NAVEX laser system.

نویسنده

  • Jan Venter
چکیده

PURPOSE To determine the predictability, efficacy, safety, and stability of LASIK using custom ablation with the NIDEK Advanced Vision Excimer Laser System (NAVEX). METHODS One hundred twenty eyes underwent LASIK for myopia using the OPDCAT algorithm. Refractive outcomes and the change in higher order aberrations, coma, and spherical aberrations were analyzed. Postoperative follow-up ranged from 6 to 18 months. RESULTS Mean postoperative spherical equivalent refraction was -0.05 diopters (D) (range: -0.92 to +0.88 D). Uncorrected visual acuity was 1 or better in 109 (91%) eyes and 1.2 or better in 47 (39%) eyes. Postoperative spherical equivalent refraction was within +/- 0.50 D of intended correction in 110 (92%) eyes. Fifty-two (43%) eyes gained 1 or more lines of best spectacle-corrected visual acuity (BSCVA), and no eyes lost more than 1 line of BSCVA. Higher order aberrations root-mean-square increased by 0.053 microm postoperatively. Patients with preoperative higher order aberrations > or = 0.3 microm were less likely to have induced higher order aberrations. CONCLUSIONS Wavefront-guided OPDCAT treatments with the NIDEK NAVEX system for myopia are safe and effective with excellent visual acuity and refractive outcomes. Eyes with > or = 0.3 microm of higher order aberrations preoperatively will benefit more from OPDCAT treatment than eyes with a smaller amount of higher order aberrations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Wavefront- versus topography-guided customized ablations with the NIDEK EC-5000 CX II in surface ablation treatment: refractive and aberrometric outcomes.

PURPOSE To compare the long-term refractive outcomes and changes in higher order wavefront aberrations in patients undergoing photorefractive keratectomy (PRK) with topography-guided (CATz) or wavefront-guided (OPDCAT) ablation algorithm using the NIDEK Advanced Vision Excimer Laser System (NAVEX). METHODS A retrospective 12-month follow-up study was conducted of 226 eyes undergoing PRK. The ...

متن کامل

Outcomes of NIDEK optical path difference custom ablation treatments (OPDCAT) for myopia with or without astigmatism.

PURPOSE To report refractive and visual acuity outcomes using wavefront-guided optical path difference custom ablation treatments (OPDCAT; NIDEK Co Ltd) for myopia and myopic astigmatism. METHODS One hundred eyes of 50 patients with preoperative manifest refraction spherical equivalent (MRSE) of 4.62+/-1.30 diopters (D) (range: -1.38 to -7.25 D) with mean astigmatism of -0.57+/-0.37 D (range:...

متن کامل

Q-factor customized ablation profile for the correction of myopic astigmatism.

PURPOSE To compare the results of the Q-factor customized aspheric ablation profile with the wavefront-guided customized ablation pattern for the correction of myopic astigmatism. SETTING Institute for Refractive and Ophthalmic Surgery, Zurich, Switzerland. METHODS Thirty-five patients were enrolled in a controlled study in which the nondominant eye was treated with the Q-factor customized ...

متن کامل

Photorefractive keratectomy for primary myopia using NIDEK topography-guided customized aspheric transition zone.

PURPOSE To report the outcomes of topography-guided photorefractive keratectomy (PRK) for the treatment of myopia with or without astigmatism using the customized aspheric transition zone (CATz) ablation algorithm. METHODS In this study, 335 eyes underwent PRK using the NIDEK Advanced Vision Excimer laser platform (NAVEX). Mean preoperative manifest refraction spherical equivalent was -4.42+/...

متن کامل

Slit skiascopic-guided ablation using the Nidek laser.

PURPOSE To present the approach of using a scanning slit refractometer (the ARK 10000) in conjunction with a corneal topography system to guide customized corneal ablation. This diagnostic system is coupled with the Nidek EC-5000 system which combines scanning slit and a scanning small area ablation (1.0 mm) to perform a customized ablation. METHODS The ARK 10000 diagnostic system which conta...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of refractive surgery

دوره 24 5  شماره 

صفحات  -

تاریخ انتشار 2008