Anatomical bases for the insertion of zygomatic implants.
نویسندگان
چکیده
PURPOSE The purpose of this study was to obtain anatomical information for installing four zygomatic implants, by measurements of maxillae and zygomata. MATERIALS AND METHODS Linear and angular measurements were obtained from the maxillae and zygomata of 40 dry skulls. RESULTS Based on mean and standard deviation values, the installation angle of the additional implant in the four zygoma technique was between 25 degrees and 47 degrees , and that of the conventional zygomatic implant was between 39 degrees and 62 degrees . The distance between the alveolar crest in the canine region and the lateral margin of the orbital socket was 53.42 mm, and between the alveolar crest in the premolar region and the area closest to the lateral margin of the orbital socket was 42.47 mm. CONCLUSIONS When the angle of installation of the additional implant is less than 25 degrees and that of the conventional zygomatic implant is less than 39 degrees , perforation of the maxilla, zygoma, or the infratemporal fossa must be avoided. When the angle of installation of an additional implant is greater than 47 degrees and that of the conventional zygomatic implant is greater than 62 degrees , perforation of the orbital floor must be avoided. The length of an additional implant was greater than the length of a conventional zygomatic implant, and should be measured prior to drilling, because the greatest value found for this distance was 61.94 mm, while the maximum length of the zygomatic implants currently available on the market is 52.5 mm.
منابع مشابه
Rehabilitation of severely resorbed maxillae with zygomatic implants: an update.
Studies highlight the zygomatic bone as a suitable anatomical structure for implant placements since they cross four corticals. Zygomatic implants were described by Branemark in 1988, since then zygomatic implants are indicated in maxillae with atrophy of the posterior area. They have been used in systemic diseases associated with bone loss in this area, and in patients who have suffered radica...
متن کاملAccuracy evaluation of computed tomography-derived stereolithographic surgical guides in zygomatic implant placement in human cadavers.
Presurgical planning is essential to achieve esthetic and functional implants. For implant planning and placement, the association of computer-aided design (CAD) and computer-aided manufacturing (CAM) techniques furnishes some advantages regarding tridimensional determination of the patient's anatomy and fabrication of both anatomic models and surgical guides. The goal of this clinical study wa...
متن کاملThe reverse zygomatic implant: a new implant for maxillofacial reconstruction.
This case report describes the rehabilitation of a patient who had been treated with a hemimaxillectomy, reconstruction with a latissimus dorsi vascularized free flap, and radiotherapy for carcinoma of the sinus some years previously. Limited jaw opening, difficult access through the flap to the bony site, and the very small amount of bone available in which to anchor the implant inspired the d...
متن کاملCombined immediate loading of zygomatic and mandibular implants: a preliminary 2-year report of 19 patients.
PURPOSE A retrospective study was performed to evaluate the feasibility of simultaneous use of immediately loaded zygomatic and mandibular implants for full maxillomandibular restoration. MATERIALS AND METHODS A total of 40 zygomatic and 112 conventional implants were placed in 19 edentulous and partially edentulous patients and restored with full-arch acrylic resin prostheses within 3 hours ...
متن کاملAccuracy of drilling guides for transfer from three-dimensional CT-based planning to placement of zygoma implants in human cadavers.
The accuracy of surgical drilling guides was assessed for placement of zygoma implants. Six zygoma fixtures of length 45 mm (Nobel Biocare, Göteborg, Sweden) were placed in three formalin-fixed human cadavers using surgical drilling guides. The fabrication of these custom-made drilling guides was based on three-dimensional computerized tomography (3D-CT) data for the maxillary-zygomatic complex...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical implant dentistry and related research
دوره 10 4 شماره
صفحات -
تاریخ انتشار 2008