Finger-Stick Glucose Monitoring
نویسندگان
چکیده
S ince its introduction three decades ago, self-monitoring of blood glucose (SMBG) using finger-stick blood samples, test strips, and portable meters has aided diabetes management, principally by enabling patients— particularly those treated with insulin—to become full partners along with health professionals in striving for excellent glycemic control. Over time the use of glucose meters has become easier and faster with smaller and smaller blood samples yielding results in a matter of seconds. For this reason, glucose meters are now increasingly used in hospital wards, intensive care units, and other facilities such as dialysis units and infusion centers to provide point-of-care results that would take much longer through routine laboratory channels. This technology has largely taken the guess work out of diabetes management. Without such technology, intensive glucose control such as that achieved in the Diabetes Control and Complications Trial may not have been demonstrated to prevent or decrease microvascular complications; insulin pump therapy would not really be practical; and hypoglycemia would remain an even greater source of anxiety for patients and their families than it already is. We have come to rely so much on finger-stick glucose that it is easy to forget its limitations. In considering this we will discuss accuracy, specificity, and, in light of those, inappropriate usage.
منابع مشابه
Use of an automated device for alternative site blood glucose monitoring.
OBJECTIVE To evaluate the accuracy, comfort, and ease of use of a new automated device for blood glucose monitoring using the arm as an alternative sampling site. RESEARCH DESIGN AND METHODS These studies use an automated hand-held device that applies a small vacuum, lances the skin, transfers blood onto an electrochemical test strip, and measures glucose. Patients who had type 1 or type 2 di...
متن کاملAccuracy of a new real-time continuous glucose monitoring algorithm.
BACKGROUND Through minimally invasive sensor-based continuous glucose monitoring (CGM), individuals can manage their blood glucose (BG) levels more aggressively, thereby improving their hemoglobin A1c level, while reducing the risk of hypoglycemia. Tighter glycemic control through CGM, however, requires an accurate glucose sensor and calibration algorithm with increased performance at lower BG ...
متن کاملContinuous glucose monitoring in the management of diabetes mellitus.
Continuous glucose monitors (CGMs) measure interstitial fluid (ISF) glucose, and provide information about continuous glucose fluctuations that is not otherwise captured by intermittent blood glucose testing. CGMs may benefit patients having difficulty controlling their blood sugar or during initiation or monitoring of insulin pump use. CGMs require calibration with finger-stick tests and suppl...
متن کاملNoninvasive Technique for Estimating Blood Glucose Levels among Diabetic Patients.
AIM The present study was aimed to assess the fasting and postprandial gingival crevicular blood (GCB) glucose and finger stick blood glucose measurements using a glucometer. MATERIALS AND METHODS A total of 30 subjects with periodontitis and positive bleeding on probing were considered. Subjects were instructed to report to the department after overnight fasting. Gingival crevicular blood sa...
متن کاملThe effect of an instant hand sanitizer on blood glucose monitoring results.
BACKGROUND People with diabetes mellitus are instructed to clean their skin prior to self-monitoring of blood glucose to remove any dirt or food residue that might affect the reading. Alcohol-based hand sanitizers have become popular when soap and water are not available. The aim of this study was to determine whether a hand sanitizer is compatible with glucose meter testing and effective for t...
متن کامل