Implementation and evaluation of patient-specific three-dimensional internal dosimetry.

نویسندگان

  • K S Kolbert
  • G Sgouros
  • A M Scott
  • J E Bronstein
  • R A Malane
  • J Zhang
  • H Kalaigian
  • S McNamara
  • L Schwartz
  • S M Larson
چکیده

UNLABELLED Current methods for calculating the absorbed dose in a target region from a source region rely on a standard "reference man" geometry and assume an uniform distribution of radiolabel. While this approach is acceptable at the low levels of radioisotope administered for most diagnostic purposes, the generality of the calculations is not adequate for doses at the higher levels required for therapy and is not easily extendible to tumor dosimetry. METHODS We have developed an integrated system which utilizes patient anatomy and radionuclide distribution in the calculation of absorbed dose rate or total dose to any user-defined target region. Images of radionuclide distribution (PET/SPECT) are registered to anatomic images (CT/ MRI) and then entered into a three-dimensional internal dosimetry software system (3D-ID) where regions of interest are defined. Dose calculations are performed by the mathematical convolution between a user-specified, dose-point kernel with the activity in the source volume over the target volume. The resulting dose rate distribution may be scaled by cumulated activity to yield absorbed dose. In addition to calculating the mean dose, dose-volume histograms may be generated which plot absorbed dose with respect to percent of volume. The method was evaluated using selected standard man phantom organs. RESULTS Dose estimates for two patient studies are included to illustrate differences between patient-specific and MIRD-based calculations. The package provides an alternative approach to image display and three-dimensional internal dose calculations. CONCLUSION The dose-volume histogram representation of absorbed dose to a target volume provides valuable information in assessing tumor control probability and normal tissue toxicity.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of a fast method of EPID-based dosimetry for IMRT and Comparison with 3D EPID-based dosimetry system using conventional two- and three-dimensional detectors for VMAT

Introduction: Electronic portal imaging devices (EPIDs) could potentially be useful for intensity-modulated radiation therapy (IMRT) and VMAT QA. The data density, high resolution, large active area, and efficiency of the MV EPID make it an attractive option. However, EPIDs were designed as imaging devices, not dosimeters, and as a result they do not inherently measure dose in ...

متن کامل

Evaluation of Full scatter convolution algorithm based Treatment Planning System performance in the presence of inhomogeneities using three-dimensional film dosimetry

Introduction: Inclusion of inhomogeneities such as air-filled cavities in the head and neck treatment fields may result in potential dosimetric disagreement which was caused by electronic disequilibrium. Most of treatments planning systems (TPS) are not able to predict dose distribution of inhomogeneous regions accurately. EBT2 films are used frequently in radiotherapy quality ass...

متن کامل

Image-based versus atlas-based patient-specific S-value assessment for Samarium-153 EDTMP cancer palliative care: A short study

Introduction: Use of SPECT/CT data is the most accurate method for patient-specific internal dosimetry when isotopes emit single gamma rays. The manual or semi-automatic segmentation of organs is a major obstacle that slows down and limits the patient-specific dosimetry. Using digital phantoms that mimic patient’s anatomy can bypass the segmentation step and facilitate the dosi...

متن کامل

Evaluation of Three-dimensional Treatment Planning System (TPS) performance in dose calculation of virtual wedged fields using film dosimetry

Introduction: Nowadays radiotherapy plays an important role in cancer treatment. Different radiotherapy techniques improvement emphasizes on using of the precise ، appropriate and useful algorithms. one of these techniques are wedged which is used in radiotherapy to compensate missing tissues and create a uniform dose distribution in tissues. The Siemens Artiste linear accelera...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of nuclear medicine : official publication, Society of Nuclear Medicine

دوره 38 2  شماره 

صفحات  -

تاریخ انتشار 1997