Comparison of capability of abdominal 320-detector row CT and of 16-detector row CT for small vasculature assessment.
نویسندگان
چکیده
The purpose of our study was to compare the capability of the 320-detector row CT (area-detector CT: ADCT) using the step-and-shoot scan protocol for small abdominal vasculature assessment with that of the 16-detector row CT using the helical scan protocol. Contrast-enhanced abdominal CT for preoperative assessment was administered to 25 patients, 18 of whom, suspected of having lung cancer, underwent ADCT using the step-and-shoot scan protocol, while the remaining 7, suspected of having renal cell carcinoma, underwent 16-MDCT using the helical scan protocol. Two experienced abdominal radiologists independently assessed renal interlobar and arcuate as well as mesenteric marginal (Griffith point) arteries by means of a 5-point visual scoring systems. Kappa analysis was used for evaluation of interobserver agreement. To compare the visualization capability of the two systems, the scores for each of the arteries were compared by using the Mann-Whitney U-test. Overall interobserver agreements for both systems were almost perfect (κ>0.78). Visualization scores for renal interlobar and arcuate, (p<0.0001) and mesenteric marginal (Griffith point) arteries (p<0.05) were significantly higher for ADCT than for 16-detector row CT. ADCT using the step-and-shoot scan protocol for small abdominal vasculature assessment can be considered superior to 16-detector row CT using the helical scan protocol.
منابع مشابه
The efficacy of 320-detector row computed tomography for the assessment of preoperative pulmonary vasculature of candidates for pulmonary segmentectomy.
OBJECTIVES The purpose of this study was to compare the efficacy of 320-detector row computed tomography (CT) with that of 64-detector row CT for three-dimensional assessment of pulmonary vasculature of candidates for pulmonary segmentectomy. METHODS We included 32 patients who underwent both 320- and 64-detector CT before pulmonary segmentectomy, which was performed by cutting the pulmonary ...
متن کاملCancerogenesis Risks between 64 and 320 Row Detector CT for Coronary CTA Screening
OBJECTIVES This study compares cancerogenesis risks posed by the 64 row detector and the 320 row detector computed tomography scanners used during coronary computed tomography angiography (CCTA) following decennial screening guidelines. MATERIAL AND METHODS Data of the radiation absorbed after CCTA by lung, thyroid, and female breast in patients between 50 and 70 years of age obtained from pr...
متن کاملDose exposure of patients undergoing comprehensive stroke imaging by multidetector-row CT: comparison of 320-detector row and 64-detector row CT scanners.
BACKGROUND AND PURPOSE Recently introduced 320-detector row CT enables whole brain perfusion imaging compared to a limited scanning area in 64-detector row CT. Our aim was to evaluate patient radiation exposure in comprehensive stroke imaging by using multidetector row CT consisting of standard CT of the head, CTA of cerebral and cervical vessels, and CTP. MATERIAL AND METHODS Organ doses wer...
متن کاملRecent Update on Radiation Dose Assessment for the State-of-the-Art Coronary Computed Tomography Angiography Protocols
OBJECTIVES This study aimed to measure the absorbed doses in selected organs for prospectively ECG-triggered coronary computed tomography angiography (CCTA) using five different generations CT scanners in a female adult anthropomorphic phantom and to estimate the effective dose (HE). MATERIALS AND METHODS Prospectively ECG-triggered CCTA was performed using five commercially available CT scan...
متن کاملMultiplanar and 3D imaging of the central airways: comparison of image quality and radiation dose of single-detector row CT and multi-detector row CT at differing tube currents in dogs.
PURPOSE To compare in an animal model the image quality of multiplanar reformation and three-dimensional (3D) reconstruction images of the central airways by using single-detector row computed tomography (CT) and multi-detector row CT at varied tube currents and to compare radiation dose. MATERIALS AND METHODS Five dogs each underwent five consecutive helical CT examinations (one single-detec...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Kobe journal of medical sciences
دوره 56 4 شماره
صفحات -
تاریخ انتشار 2011