Experimental study on penetration of dental implants into the maxillary sinus in different depths
نویسندگان
چکیده
UNLABELLED The exposing of dental implant into the maxillary sinus combined with membrane perforation might increase risks of implant failure and sinus complications. OBJECTIVE The purpose of this study was to investigate the effects of the dental implant penetration into the maxillary sinus cavity in different depths on osseointegration and sinus health in a dog model. MATERIAL AND METHODS Sixteen titanium implants were placed in the bilateral maxillary molar areas of eight adult mongrel dogs, which were randomly divided into four groups according to the different penetrating extents of implants into the sinus cavities (group A: 0 mm; group B: 1 mm; group C: 2 mm; group D: 3 mm). The block biopsies were harvested five months after surgery and evaluated by radiographic observation and histological analysis. RESULTS No signs of inflammatory reactions were observed in any maxillary sinus of the eight dogs. The tips of the implants with penetrating depth of 1 mm and 2 mm were found to be fully covered with newly formed membrane and partially with new bone. The tips of the implants with penetrating depth over 3 mm were exposed in the sinus cavity and showed no membrane or bone coverage. No significant differences were found among groups regarding implant stability, bone-to-implant contact (BIC) and bone area in the implant threads (BA). CONCLUSIONS Despite the protrusion extents, penetration of dental implant into the maxillary sinus with membrane perforation does not compromise the sinus health and the implant osseointegration in canine.
منابع مشابه
Potential adverse events of endosseous dental implants penetrating the maxillary sinus: long-term clinical evaluation.
OBJECTIVES/HYPOTHESIS The aim of this study was to evaluate the nature and incidence of long-term maxillary sinus adverse events related to endosseous implant placement with protrusion into the maxillary sinus. STUDY DESIGN Retrospective cohort study. METHODS All patients who underwent placement of endosseous dental implants with clinical evidence of implant penetration into the maxillary s...
متن کاملOutcome of short implants as an alternative to sinus lift surgery and standard-length implants for rehabilitation of atrophic posterior maxilla: A clinical trial
Background and Aims: The aim of this study was to assess the outcome of short implants (<8 mm length) as an alternative to sinus lift surgery and placement of standard-length implants (10-12 mm length) for rehabilitation of atrophic posterior maxilla. Materials and Methods: In this prospective clinical trial, 26 patients with 6-7 mm of residual alveolar bone height in their atrophic posterior ...
متن کاملThe Effect of Thickness on Sealing Ability of Calcium Enriched Cement as a Coronal Seal Barrier
Abstract Introduction: Thickness of a coronal seal barrier is an important factor for preventing microleakage. The aim of this in vitro study was to compare the sealing ability of two different thicknesses of calcium Enriched Mixture (CEM) cement as a coronal seal barrier. Methods: A total of 40 canals of extracted maxillary central incisors were instrumented and obturated using lateral compa...
متن کاملبررسی دقت توموگرافی خطی در تعیین محل حفره بینی و سینوس ماگزیلاری1
Background and Aim: Accurate measurement of bone height and width is essential prior to dental implant placement. The method of surgery as well as, the type and size of implants are determined according to dimensions of the residual bone. The purpose of this study was to evaluate the accuracy of linear tomography in localization of the floor of nasal fossa and maxillary sinus, and to determine ...
متن کاملEvaluation of prevalence and pattern of maxillary sinus mucosal thickening in cone beam computed tomography of dental implant candidates in Shiraz, Iran
BACKGROUND AND AIM: This study aimed to assess maxillary sinus floor membrane thickness and ostium patency (OP) in patients undergoing cone beam computed tomography (CBCT) evaluation for implant placement in the posterior maxilla. Mucosal thickening (MT) could be cause of post-operative complications in implant procedures; awareness of this incidence could help proper detection and further succ...
متن کامل