The maternal plasma levels and placental transfer of bupivacaine following epidural analgesia.

نویسندگان

  • J Thomas
  • C R Climie
  • L E Mather
چکیده

The maternal plasma levels of bupivacaine following epidural administration of 0.5 per cent solution with 1/200,000 adrenaline were determined in twelve patients in labour. After 10 ml (50 mg) peak concentrations occurred 15-30 min later and ranged from 0.22 ^ug/ml to 0.60 ,«g/ml. Plasma levels fell gradually with time after the peak until by 3 hours after injection they were all well below 0.2 jUg/ml. Maternal and umbilical plasma levels of bupivacaine were determined at delivery. The ratio of the foetal to maternal levels varied from 0.14 to 0.86. The highest foetal plasma level obtained in the series was 0.25 wg/ml and the highest maternal level was 0.68 /ig/ml. This value was reached after three 10-ml injections of 0.5 per cent bupivacaine with 1/200,000 adrenaline. The 1-min Apgar scores ranged from 7 to 10.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Epidural Analgesia with Bupivacaine, Ketamine, and the Combination of Bupivacaine and Ketamine in Sheep

Objective- To evaluate the effects of bupivacaine (B), ketamine (K), and a combination of bupivacaine and ketamine (BK) after lumbosacral epidural analgesia in sheep.   Design- Experimental study.   Animals- Nine healthy male and non-pregnant female Iranian Chall sheep with mean body weight of 38.9 ± 15.1 kg.   Procedures- Animals were selected randomly and three treatments administered. The ...

متن کامل

Bupivacaine 0.125% in epidural block analgesia during childbirth: maternal and foetal plasma concentrations.

The maternal plasma concentration of bupivacaine has been determined in 19 patients receiving a continuous epidural block during labour, using bupivacaine 0.125% with adrenaline 1:400,000. The plasma concentration of bupivacaine rarely exceeded 0.18 /*g/ml. Bupivacaine does not accumulate in the maternal blood when such low concentrations are used. The plasma concentration of bupivacaine has al...

متن کامل

Effect of time and adrenaline on the feto-maternal distribution of bupivacaine.

Following lumbar extradural analgesia with 0.5% bupivacaine, the placental transfer of bupivacaine was examined in 40 women undergoing elective and 40 women undergoing emergency Caesarean section. Within each group, the patients received randomly either plain bupivacaine or bupivacaine with adrenaline 1 in 200,000. Plasma bupivacaine concentrations were measured in blood samples taken simultane...

متن کامل

The concentration of bupivacaine in fetal organs during obstetrical epidural analgesia.

The concentration of bupivacaine in organs of non-viable human fetuses after obstetrical epidural analgesia in customary doses was investigated. The concentrations were determined with a gas chromatograph. The material consisted of a fetus who died following termination in the 24th week of pregnancy three minutes after birth without spontaneous respiration. The other fetus was born maturely in ...

متن کامل

Comparison of bupivacaine and ropivacaine in combination with fentanyl used for walking epidural anesthesia in labor

OBJECTIVE Effective pain relief during labor is essential to reduce maternal and perinatal morbidity arising due to pain-induced maternal sympathetic activation, and to avoid unnecessary cesarean sections performed due to maternal anxiety. Walking epidural analgesia on labor reveals lower pain scores, leading to higher maternal satisfaction with better cardiovascular and pulmonary physiology. D...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • British journal of anaesthesia

دوره 41 12  شماره 

صفحات  -

تاریخ انتشار 1969