Master/slave interferometry - ideal tool for coherence revival swept source optical coherence tomography.

نویسندگان

  • Adrian Bradu
  • Sylvain Rivet
  • Adrian Podoleanu
چکیده

In this paper, we demonstrate that the master slave (MS) interferometry method can significantly simplify the practice of coherence revival swept source optical coherence tomography (OCT) technique. Previous implementations of the coherence revival technique required considerable resources on dispersion compensation and data resampling. The total tolerance of the MS method to nonlinear tuning, to dispersion in the interferometer and to dispersion due to the laser cavity, makes the MS ideally suited to the practice of coherence revival. In addition, enhanced versatility is allowed by the MS method in displaying shorter axial range images than that determined by the digital sampling of the data. This brings an immediate improvement in the speed of displaying cross-sectional images at high rates without the need of extra hardware such as graphics processing units or field programmable gate arrays. The long axial range of the coherence revival regime is proven with images of the anterior segment of healthy human volunteers.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

تکرارپذیری و میزان تشابه اندازه‌گیری‌های بیومتری توسط دستگاه swept source optical coherence (OA2000) و partial coherence interferometry (IOL Master) به عنوان مرجع

هدف: بررسی تکرارپذیری و میزان تشابه اندازه‌گیری پارامترهای ضخامت لنز (Lens Thickness, LT)، عمق اتاق قدامی (Anterior Chamber Depth, ACD)، طول محوری (Axial Length, AL) و کراتومتری (Keratometry, K) توسط دستگاه جدید ۲۰۰۰OA- و مقایسه آن با دستگاه ۵۰۰IOL Master. روش پژوهش: در این مطالعه مقطعی، بیماران دارای کاتاراکت در یک یا دو چشم برای ورود به مطالعه انتخاب شدند. پارامترهایAL, ACD, LT, K توسط دستگاه...

متن کامل

Estimation of Earthquake Damage Through Radar Interferometry (Case study: Bam 2003 Earthquake)

The estimate of the damage caused by the earthquake and other natural disasters in the first days after the occurrence of these events can provide a quick damages assessment and help to manage the crisis. Several methods are available to investigate the extent of earthquake’s damage. Optical remote sensing, photogrammetric methods (UAVs and LIDARs), radar interferometry (InSAR) and field observ...

متن کامل

Complete complex conjugate resolved heterodyne swept source optical coherence tomography using a dispersive optical delay line: erratum

We correct an error in our previous paper [Biomed. Opt. Express 2, 1218 (2011)] which led to an erroneous conclusion that a dispersive optical delay line (DODL) used in a swept source optical coherence tomography (SSOCT) system generated a pure phase modulation allowing for complex conjugate artifact removal in Fourier domain OCT via optical heterodyning. We now understand that an alternate phe...

متن کامل

Complex conjugate resolved heterodyne swept source optical coherence tomography using coherence revival

We describe a simple and low-cost technique for resolving the complex conjugate ambiguity in Fourier domain optical coherence tomography (OCT) that is applicable to many swept source OCT (SSOCT) systems. First, we review the principles of coherence revival, wherein an interferometer illuminated by an external cavity tunable laser (ECTL) exhibits interference fringes when the two arms of the int...

متن کامل

Phase-sensitive swept-source interferometry for absolute ranging with application to measurements of group refractive index and thickness.

Interferometric range measurements using a wavelength-tunable source form the basis of several measurement techniques, including optical frequency domain reflectometry (OFDR), swept-source optical coherence tomography (SS-OCT), and frequency-modulated continuous wave (FMCW) lidar. We present a phase-sensitive and self-referenced approach to swept-source interferometry that yields absolute range...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Biomedical optics express

دوره 7 7  شماره 

صفحات  -

تاریخ انتشار 2016