SPIO-enhanced MR Evaluation of Regional Hepatic Blood Flow
نویسندگان
چکیده
PURPOSE: To establish the methods of semi-quantification of regional hepatic blood flow using paramagnetic iron oxide (SPIO)-enhanced dynamic MR imaging and two-input, one-compartment model in phantom and clinical studies. METHOD AND MATERIALS: The phantom study was conducted using a 1.5-T MR scanner (Achieva, Philips Medical Systems) and SPIO (Resovist, Bayer Healthcare)-agarose phantom. 2D-GRE (TE: 2.3/4.6), 3D-GRE, 2D-GRE-EPI, 2D-GRE (TE: 6.9), and T2W/PDW fast SE sequences were evaluated. In clinical study, 37 patients (25 men and 12 women, mean: 62.1 years, Child-Pugh A:30, B: 7) who were suspected to have hepatic tumors (hepatic metastasis; 18 (colorectal: 13, carcinoid: 2, gastric: 1, pancreas: 1, islet cell tumor: 1), HCC: 11, FNH: 1, hyperplastic nodule: 1, hemangioma: 1, abscess: 1, simple cyst: 1, portal aneurysm: 1), underwent hepatic MR perfusion study. Dynamic scans (3D-GRE, TR: 0.76, TE: 1.97, FA: 10, Matrix: 128 x 128, Acquisition: 1, fat-suppression, 10mm x 10 slices, parallel imaging factor: 3) were conducted using the same MR scanner 0 90 sec after bolus injection of SPIO (0.016 ml/kg, diluted to 20ml, 3ml/sec). The center of scan volume was set at the hepatic hilum. A software for semi-quantification of regional hepatic blood flow by two-input and one-compartment model was developed on MATLAB ver. 6 (The MathWorks, Inc.). Input functions were generated from the ROIs on abdominal aorta and main portal vein (Fig.1.). Arterial and portal perfusion maps were created (Fig.2 & 3.) and ROIs were placed on normal hepatic parenchyma as large as possible avoiding large vessels, tumors, and affected hepatic parenchyma. Mean hepatic arterial and portal blood flows (ml/min/100ml) (AHBF and PHBF), and hepatic arterial perfusion ratio (arterial blood flow / total blood flow x 100 %) (HAPR) were estimated and compared with Child-Pugh class (n = 37) and ICGR15 (n = 18). RESULTS: In phantom study, 3D-GRE sequences showed the best linear relation between SPIO concentration and signal intensity over the range of 0.01 2mM (Fig.4.). Dilution ratio and injection rate of SPIO in clinical study were set considering the dilution ratio during passing through the heart. In clinical study, the mean AHBF, PHBF, and HAPR were 30.2 ± 11.6, 62.3 ± 26.5, and 33.4 ± 9.6, respectively. AHBF was significantly greater (p < 0.05), and HAPR and PHBF tended to be greater in Child-Pugh B group than A. Weak negative correlation was found between HAPR and ICGR15 (γ: -0.28). CONCLUSION: Regional hepatic blood flow can be estimated by SPIO-enhanced dynamic MR imaging and two-input, one-compartment model. The estimated values have the potential to be used for evaluation of regional hepatic function.
منابع مشابه
Evaluation of superparamagnetic iron oxide for MR imaging of liver injury: proton relaxation mechanisms and optimal MR imaging parameters.
PURPOSE To investigate the proton relaxation mechanisms and the optimal MR imaging parameters in superparamagnetic iron oxide (SPIO)-enhanced MR imaging of liver injury. METHODS A liver injury model was created in the rat using carbon tetrachloride. The T1 and T2 relaxation effects of SPIO in normal and injured liver were estimated by ex vivo relaxometry. In vivo laser confocal microscopy of ...
متن کاملSuperparamagnetic iron oxide-enhanced MR imaging of head and neck lymph nodes.
PURPOSE To compare findings on superparamagnetic iron oxide (SPIO)-enhanced magnetic resonance (MR) images of the head and neck with those from resected lymph node specimens and to determine the effect of such imaging on surgical planning in patients with histopathologically proved squamous cell carcinoma of the head and neck. MATERIALS AND METHODS Thirty patients underwent MR imaging with no...
متن کاملDiffusion-Weighted MR Imaging before and after Contrast Enhancement with Superparamagnetic Iron Oxide for Assessment of Hepatic Metastasis
PURPOSE The purpose of our study was to validate diffusion-weighted MRI (DWI) before and after superparamagnetic iron oxide (SPIO) injection for assessment of hepatic metastases. MATERIALS AND METHODS Eighty-six hepatic metastases (size range, 0.3-4.7 cm; mean, 1.5 cm) verified pathologically or by follow-up imaging studies in 22 consecutive patients (17 men and 5 women; 44-83 years; mean age...
متن کاملCorrection: Quantitative Evaluation of the Reticuloendothelial System Function with Dynamic MRI
PURPOSE To evaluate the reticuloendothelial system (RES) function by real-time imaging blood clearance as well as hepatic uptake of superparamagnetic iron oxide nanoparticle (SPIO) using dynamic magnetic resonance imaging (MRI) with two-compartment pharmacokinetic modeling. MATERIALS AND METHODS Kinetics of blood clearance and hepatic accumulation were recorded in young adult male 01b74 athym...
متن کاملUtility of multiple-echo data image combination sequence for SPIO-enhanced T2*-weighted MR imaging of liver MRI at 3.0 T system
Introduction At 3.0 T MR system, superparamagnetic iron oxide (SPIO)-enhanced liver magnetic resonance imaging (MRI) may have the theoretical advantage of high SNR and high liver to lesion contrast, because of stronger susceptibility effect compared with that at 1.5 T. On T2*-weighted gradient recalled echo (GRE) sequences essential for SPIO-enhanced liver MRI, positive effects of 3T on lesion-...