'Smart' solutions for paroxysmal atrial fibrillation?

نویسندگان

  • Lars Grieten
  • Thijs Vandenberk
  • Dieter Nuyens
چکیده

Based on the review of Carpenter and Frontera we present a case of a 66-year-old female patient who was implanted with an implantable loop recorder (ILR) (LinQ, Medtronic) due a history of unexplained syncope and symptoms of palpitations. After the procedure the patient was provided with a smartwatch device (E4, Empatica), which measures the photoplethysmography (PPG) signal at the wrist, and an iPhone 5S smartphone with a custom-made application (FibriCheck), which measures the PPG signal in the tip of the finger using the smartphone camera. She was instructed to wear the smartwatch during the nights to perform at least 7 h of continuous measurements. After waking and removing the watch for charging, she was instructed to perform spot-check measurements (60 s) using a smartphone application (FibriCheck). In total, two standard recordings were obtained per day and additional measurements upon presentation of symptoms. All of these measurements were performed over a period of 4 months. Overall compliance rates for the smartwatch measurements and for the smartphone measurements were 98% and 107%, repectively, indicating a good adherence for long-term monitoring application. In total, the ILR detected nine episodes of paroxysmal AF with episodes ranging between 40 min to 3 h. After synchronizing the data streams between the ILR, smartwatch, and smartphone, all AF events that occurred while wearing or using one of the smart devices were picked-up and identified as AF (as shown in Figure 1). Our in-house-developed algorithms identified episodes of AF when the erratic behaviour of consecutive RR intervals exceeds pre-defined boundaries. Using RR variability for the detection of AF is commonly accepted in literature. Figure 1 shows a normal sinus rhythm as well as episodes of atrial fibrillation. The upper panel represents the ILR results with a normal sinus rhythm as well as the onset of an AF event. This onset is synchronized with the PPG signal of the smartwatch (middle panel). The bottom panel shows two measurements from a smartphone recording using the FibriCheck application.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Detection of paroxysmal atrial fibrillation by 30-day event monitoring in cryptogenic ischemic stroke: the Stroke and Monitoring for PAF in Real Time (SMART) Registry.

BACKGROUND AND PURPOSE Patients with cryptogenic ischemic stroke may have undetected paroxysmal atrial fibrillation (PAF). We established the Stroke and Monitoring for PAF in Real Time (SMART) Registry to determine the yield of 30-day outpatient PAF monitoring in cryptogenic ischemic stroke. METHODS The SMART Registry was a 3-year, prospective multicenter registry of 239 patients with cryptog...

متن کامل

Neural mechanisms of paroxysmal atrial fibrillation and paroxysmal atrial tachycardia in ambulatory canines.

BACKGROUND The relationship between autonomic activation and the mechanisms of paroxysmal atrial fibrillation remains unclear. METHODS AND RESULTS We implanted a pacemaker and a radio transmitter in 7 dogs (group 1). After baseline recording, we paced the left atrium at 20 Hz for 1 week and then monitored left stellate ganglion nerve activity, left vagal nerve activity, and left atrial electr...

متن کامل

Ablate and pace revisited: long term survival and predictors of permanent atrial fibrillation.

OBJECTIVE To assess long term mortality and identify factors associated with the development of permanent atrial fibrillation after atrioventricular (AV) node ablation for drug refractory paroxysmal atrial fibrillation. DESIGN Retrospective cohort study. SETTING UK tertiary centre teaching hospital. PATIENTS Patients admitted to the University Hospital Birmingham between January 1995 and ...

متن کامل

Correlation between left atrial appendage morphology and flow velocity in patients with paroxysmal atrial fibrillation KeikoFukushima1†*,Noritoshi Fukushima1,2†,KenKato1†,Koichiro Ejima1,HirokiSato2,

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Correlation between left atrial app...

متن کامل

Serum Soluble Semaphorin 4D is Associated with Left Atrial Diameter in Patients with Atrial Fibrillation

BACKGROUND The aim of this study was to evaluate the serum soluble semaphorin 4D (sSema4D) in patients with atrial fibrillation and to investigate the relationship of serum sSema4D with left atrial diameter (LAD). MATERIAL AND METHODS We studied a total of 113 patients who were subdivided into paroxysmal and non-paroxysmal (included persistent and permanent) atrial fibrillation groups, respec...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology

دوره 19 7  شماره 

صفحات  -

تاریخ انتشار 2017