Detection of orthopaedic implants by airport metal detectors.

نویسندگان

  • Ali Abbassian
  • Balarama Datla
  • R A Brooks
چکیده

INTRODUCTION We performed a questionnaire study to establish the frequency and consequences of the detection of orthopaedic implants by airport security and to help us advise patients correctly. All published literature on this subject is based on experimental studies and no 'real-life' data are available. PATIENTS AND METHODS A total of 200 patients with a variety of implants were identified. All patients were sent a postal questionnaire enquiring about their experience with airport security since their surgery. RESULTS Of the cohort, 154 (77%) patients responded. About half of the implants (47%) were detected, but the majority of patients (72%) were not significantly inconvenienced. When detected, only 9% of patients were asked for documentary evidence of their implant. We also found that patients with a total knee replacement (TKR) had a greater chance of detection as compared to those with a total hip replacement (THR; 71% versus 31%; P = 0.03). CONCLUSIONS All patients, and in particular those with a TKR, can be re-assured that, although they have a fair chance of detection by airport security, a major disruption to their journey is unlikely. We advise that documentation to prove the presence of an orthopaedic implant should be offered to those who are concerned about the potential for inconvenience, but such documentation is not required routinely.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Airport detectors and orthopaedic implants.

As a result of the rising threats of terrorism, airport security has become a major issue. Patients with orthopaedic implants are concerned that they may activate alarms at airport security gates. A literature overview showed that the activation rate of the alarm by hand-held detectors is higher than for arch detectors (100% versus 56%). Arch detection rate has significantly increased from 0% b...

متن کامل

A fuzzy model for evaluating metal detection equipment at airport security screening checkpoints

Every passenger who travels by air is exposed to security screening. As part of this procedure, the passenger typically is screened by a walk-through metal detector. Such a device should effectively detect prohibited metal items while simultaneously ensuring adequate throughput at the security screening checkpoint. Therefore, it is necessary to evaluate both these factors when selecting an appr...

متن کامل

Detection of orthopaedic prostheses at airport security checks.

We studied the detection of joint replacements at airport security checks in relation to their weight, using two types of detector arch. A single-source, unilateral detector showed different sensitivities for implants on different sides of a test subject. All implants weighing more than 145 g were detected by one of the arches. The degree of detection was directly related to the logarithm of th...

متن کامل

Clinical and diagnostic challenges of metal implant allergy using the example of orthopaedic surgical implants

The focus of this review are allergic reactions to orthopaedic-surgical metal implants. The spectrum of metal implant associated potential allergic reactions encompasses eczema, impaired wound and fracture healing, infection-mimicking reactions, effusions, pain and loosening. Nickel, cobalt and chromium seem to be the predominant eliciting allergens. Despite the growing number of respective pub...

متن کامل

Ultraviolet detectors based on annealed zinc oxide thin films: epitaxial growth and physical characterizations

In this report, ultraviolet (UV) detectors were fabricated based on zinc oxide thin films. The epitaxial growth of zinc oxide thin films was carried out on bare glass substrate with preferred orientation to (002) plane of wurtzite structure through radio frequency sputtering technique. The structural properties indicated a dominant peak at 2θ=34.28º which was matched with JCPDS reference card N...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Annals of the Royal College of Surgeons of England

دوره 89 3  شماره 

صفحات  -

تاریخ انتشار 1997