The Ciba Corning ACS:180 benchtop immunoassay analyzer.
نویسندگان
چکیده
We describe a new clinical laboratory instrument, the ACS:180, used to automate heterogeneous immunoassay testing. The ACS:180 automates immunoassays in which paramagnetic particles are the solid phase and changes in chemiluminescence are measured. The system can accommodate both competitive and sandwich-type assay configurations. The microprocessor-based instrument fully automates each step of the assay, including sample and reagent addition, separation and wash of paramagnetic particles, and generation and acquisition of the chemiluminescent signal. The instrument has the flexibility to operate in random-access or batch mode. The time from application of sample to first result is less than 15 min; throughput is as much as 180 tests per hour.
منابع مشابه
Ciba Corning ACS:180 testosterone assay evaluated.
A fully automated direct assay of testosterone has been developed for the Ciba Corning ACS:180 immunoassay system. We have evaluated this method and compared specimen results with those from the Diagnostic Products Corp. (DPC) and Medgenix direct assays and an in-house extraction assay. Accuracy of the method was assessed by measuring GC-MS-targeted serum pools. Within-assay im- precision was <...
متن کاملSerum total testosterone: immunoassay compared with negative chemical ionization gas chromatography-mass spectrometry.
We have developed an electron capture negative chemical ionization gas chromatography-mass spectrometry (GC-MS) procedure to quantify serum testosterone in the clinically relevant range 0.69-69.3 nmol/L and used this procedure to assess Ciba Corning Diagnostics ACS:180 testosterone immunoassay. The GC-MS method involves liquid-liquid extraction of serum samples and synthesis of a pentafluoroben...
متن کاملNew noncompetitive immunoassays of small analytes.
We developed a novel noncompetitive immunoassay format for monoepitopic analytes and describe here a model assay for triiodothyronine (T3), performed on Ciba Corning's ACS:180 analyzer. Acridinium ester (AE)-labeled bivalent anti-T3 was incubated with the sample, producing AE-anti-T3/T3 complexes and unreacted AE-anti-T3. Controlled-pore glass particles (CPG) with immobilized diiodothyronine (T...
متن کاملMeasuring creatine kinase MB isoenzyme in a maintenance hemodialysis population: chemiluminometric immunoassay and electrophoresis compared.
In an effort to clarify the issue of potentially false increases in creatine kinase (EC 2.7.3.2) MB isoenzyme (CK-MB) in uremia, we evaluated the CK profile of 84 persons undergoing chronic maintenance hemodialysis. We compared the performance of a new commercial two-site chemiluminometric immunoassay of CK-MB (Magic Lite; Ciba Corning Diagnostics) with that of electrophoresis on agarose gel (C...
متن کاملClinical and analytical evaluation of two immunoassays for direct measurement of creatine kinase MB with monoclonal anti-CK-MB antibodies.
We examined the clinical and analytical performance of two immunoassays (Becton Dickinson CK-MB; Ciba-Corning Magic Lite CK-MB) in which monoclonal anti-CK-MB antibodies are used for directly measuring creatine kinase (EC 2.7.3.2) isoenzyme MB (CK-MB) in serum, and also one electrophoretic method (Ciba-Corning). Within- and between-assay precision for both immunoassays was good at the upper ref...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 36 9 شماره
صفحات -
تاریخ انتشار 1990