Sensing in Electroanalysis, Volume 8, 2013/2014
نویسندگان
چکیده
In this paper, pretreated pencil graphite electrode (Pre-PGE) was used for the determination of insulin by anodic stripping differential pulse voltammetry (DPASV). The influences of the pretreatment procedures, pH values, accumulation potential and time on the signal enhancement of insulin were optimized, and a novel electrochemical method for the determination of insulin was described. The currents obtained from DPASV measurements at optimum conditions (phosphate buffer solution pH 7.0), accumulation time (60 seconds), applied potential 400 mV vs. Ag/AgCl/3.0 mol L KCl) were linearly correlated with the concentration of insulin. Calibration curve was obtained for insulin concentrations in the range of 5.0-200.0×10 mol L .The limit of detection was found to be 2.0×10 mol L.
منابع مشابه
Sensing in Electroanalysis, Volume 8, 2013/2014
In this article, the electrochemical behavior of triethanolimine is described with a carbon paste electrode. A differential pulse voltammetric method was also developed for the determination of triethanolamine as an application to electroanalysis at a carbon paste electrode. The resultant voltammograms have revealed the irreversible electrochemical process that can be utilized to quantify the s...
متن کاملCarbon-based electrode materials for DNA electroanalysis.
This review addresses recent studies of newly developed carbon-based electrode materials and their use for DNA electroanalysis. Recently, new carbon materials including carbon nanotubes (CNT), graphene and diamond-based nanocarbon electrodes have been actively developed as sensing platforms for biomolecules, such as DNA and proteins. Electrochemical techniques using these new material-based ele...
متن کاملSensing in Electroanalysis, Volume 8, 2013/2014
Obtaining modified electrodes is a response of electrochemistry to continuous development in areas such as technology, electronics, medicine, biology and many others. Modifying layers allow scientists to build electrodes with required properties such as for example: selectivity, stability, precision, durability, range of potentials etc. The aim of the studies was to modify the surface of gold a...
متن کاملRecent nanoarchitectures in metal nanoparticle-graphene nanocomposite modified electrodes for electroanalysis.
While increasing attention has been devoted to the use of carbon-based nanomaterials or metal nanoparticles (MNPs) as electrode modifiers for electroanalysis, there is a noticeable development in studies using MNP-graphene nanocomposites or nanohybrids in very recent years. In this review, first, very recent nanoarchitectures in MNP-graphene nanocomposites for modifying electrodes (mainly in 20...
متن کاملZinc Detection in Serum by Anodic Stripping Voltammetry on Microfabricated Bismuth Electrodes.
Zinc (Zn) homeostasis is required for a functional immune system. Critically ill patients often exhibit decreased Zn serum concentrations and could potentially benefit from Zn supplementation as a therapeutic strategy. However, the conventional approaches to monitoring Zn are time consuming and costly. This work reports on detection of Zn by anodic stripping voltammetry (ASV) on bismuth electro...
متن کامل