Quantitative outcome of registration methods for correcting cardiac drift in cardiac PET/CT imaging

نویسندگان

  • Jonathon A. Nye
  • Dana Tudorascu
  • Fabio Esteves
  • John R. Votaw
چکیده

Myocardial perfusion studies suffer from artifacts caused by misalignment of the transmission and emission data due to the influences of voluntary and involuntary patient motion. Regardless of 68Ge or respiratory-averaged CT based attenuation correction and good patient cooperation, approximately 21% of perfusion studies exhibit artifacts arising from misalignment that cannot be corrected by manipulating the attenuation acquisition protocol. This misalignment, termed cardiac drift, is caused by slow-moving abdominal cavity contents that reposition the heart in the thorax and appear as myocardial uptake overlying the left CT lung in fused PET/CT images. This study evaluates three postimaging registration techniques to correct PET/CT misalignment by altering the transmission map to match myo-cardial uptake. Simulated misalignment studies were performed with a cardiac torso phantom filled with [18F]FDG at 10:1 myocardium/background. An air-filled saline bag affixed to the medial left lung surface served as a distensible lung. An initial CT acquisition was followed by successive PET acquisitions consisting of small displacements of the cardiac insert into the left lung. Phantom transmission scans were aligned to the myocardial uptake in the emission scans by applying 1) full rigid-body translations and rotations, 2) rigid-body restricted to medial / lateral and superior / inferior translation, or 3) an emission-driven method that adds myocardial tissue to the transmission scan. These methods were also applied to 10 low-likelihood coronary artery disease (CAD) patients showing signs of cardiac drift. Full rigid-body registration showed significant over-correction (p < 0.004) of activity concentrations in the artifact areas of the phantom data due the relocation of highly attenuating structures (i.e., spine). Inaccurate regional activity distributions were also observed as streaks extending from the spine and these results were replicated in the patient population. There was no significant difference between the true phantom activity concentration after correction with the emission-driven method. Misalignment corrected with the rigid-body registration results in an increase in activity concentration but fails to accurately recover the true concentration. These data suggest that a nonlinear image registration approach such as an emission-driven method results in a more uniform activity distribution throughout the myocardium, and is more appropriate for addressing the cardiac drift misalignment problem.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Factors influencing the pattern and intensity of myocardial 18F-FDG uptake in oncologic PET-CT imaging

Introduction:Myocardial 18F-FDG uptake is highly variable in oncologic whole body 18F-FDG PET/CT studies, ranging from quite intense to minimal distribution. Intense or heterogeneous myocardial 18F-FDG uptake is undesirable as it may interfere with the visual or quantitative evaluation of tumoral invasion and metastases in pericardium, myocardiu...

متن کامل

Detection of extra-cardiac hypermetabolic foci by [18F]FDG PET/CT in case of infective endocarditis and post antibiotic therapy response assessment

The diagnosis of prosthetic valve endocarditis continues to present a diagnostic challenge, due to the lower sensitivity of the modified Duke criteria and a higher percentage of negative or inconclusive echocardiography results. Diagnostic delay might result in significant morbidity/mortality. Imaging modalities like 2-[18F]fluoro-2-deoxy-D-glucose positron emission tomography/comput...

متن کامل

[18F]FDG PET/CT in a case of recurrent primary cardiac osteosarcoma

Primary cardiac osteosarcoma is a very rare malignancy with a high incidence of local recurrence and systemic metastasis, contributing to the poor prognosis. Radiological modalities are commonly used for the evaluation of cardiac masses. 2-[18F]fluoro-2-deoxy-D-glucose ([18F]FDG) positron emission tomography/computed tomography is a valuable whole-body imaging modality in ...

متن کامل

The influence of misregistration between CT and SPECT images on the accuracy of CT-based attenuation correction of cardiac SPECT/CT imaging: Phantom and clinical studies

Introduction: Integration of single photon emission computed tomography (SPECT) and computed tomography (CT) scanners into SPECT/CT hybrid systems permit detection of coronary artery disease in myocardial perfusion imaging (MPI). Misregistration between CT and emission data can produce some errors in uptake value of SPECT images. The aim of this study was evaluate the influence...

متن کامل

Is correction for metallic artefacts mandatory in cardiac SPECT/CT imaging in the presence of pacemaker and implantable cardioverter defibrillator leads?

Introduction: Metallic artifacts due to pacemaker/ implantable cardioverter defibrillator (ICD) leads in CT images can produce artifactual uptake in cardiac SPECT/CT images. The aim of this study was to determine the influence of the metallic artifacts due to pacemaker and ICD leads on myocardial SPECT/CT imaging. Methods: The study included 9 patients wh...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 17  شماره 

صفحات  -

تاریخ انتشار 2016