Comparison of a new forehead reflectance pulse oximeter sensor with a conventional digit sensor in pediatric patients.
نویسندگان
چکیده
BACKGROUND During conditions of poor perfusion, the accuracy of conventional extremity-based pulse oximeters may be limited. Limited evidence suggests that forehead perfusion may be better preserved during such periods, but pediatric experience with newer forehead reflectance sensors is limited. We prospectively compared the accuracy of a forehead reflectance sensor, the Max-Fast, with a new-generation digit sensor in pediatric patients. METHODS Pediatric patients > 10 kg and who had arterial catheters were eligible for enrollment. Blood oxygen saturation was simultaneously measured with forehead and digit sensors, and compared to corresponding CO-oximetry-measured arterial oxygen saturation values (S(aO2)) taken at the same times. We used Bland-Altman analysis to calculate the bias and precision of the forehead sensor and the digit sensor relative to the S(aO2) values. RESULTS We obtained 116 sample sets from 28 patients. The S(aO2) values ranged from 84.1% to 99.2%. The bias and precision of the forehead-to-S(aO2) difference were 0.6% and 2.7%, respectively, versus 1.4% and 2.6%, respectively, for the digit-to-S(aO2) difference (p < 0.05). Bias and precision were 0.7% and 2.6% versus 1.7% and 2.3% for the forehead and digit sensors, respectively, (p < 0.05) in patients who received vasoactive medications, compared with 0.5% and 2.8% versus 1.1% and 2.8% (p = not significant), respectively, in patients who did not receive vasoactive medications. CONCLUSIONS The Max-Fast sensor estimated S(aO2) as accurately as did a new-generation digit sensor in well-perfused pediatric patients.
منابع مشابه
Original Contributions Comparison of a New Forehead Reflectance Pulse Oximeter Sensor With a Conventional Digit Sensor in Pediatric Patients
BACKGROUND: During conditions of poor perfusion, the accuracy of conventional extremitybased pulse oximeters may be limited. Limited evidence suggests that forehead perfusion may be better preserved during such periods, but pediatric experience with newer forehead reflectance sensors is limited. We prospectively compared the accuracy of a forehead reflectance sensor, the Max-Fast, with a new-ge...
متن کاملEvaluation of a new pulse oximeter sensor.
BACKGROUND A new forehead noninvasive oxygen saturation sensor may improve signal quality in patients with low cardiac index. OBJECTIVES To examine agreement between oxygen saturation values obtained by using digit-based and forehead pulse oximeters with arterial oxygen saturation in patients with low cardiac index. METHODS A method-comparison study was used to examine the agreement between...
متن کاملValidity of pulse oximetry during maximal exercise in normoxia, hypoxia, and hyperoxia.
During exercise, pulse oximetry is problematic due to motion artifact and altered digital perfusion. New pulse oximeter technology addresses these issues and may offer improved performance. We simultaneously compared Nellcor N-395 (Oxismart XLTM) pulse oximeters with an RS-10 forehead sensor (RS-10), a D-25 digit sensor (D-25), and the Ivy 2000 (Masimo SETTM)/LNOP-Adt digit sensor (Ivy) to arte...
متن کاملPulse oximeter plethysmographic waveform changes in awake, spontaneously breathing, hypovolemic volunteers.
BACKGROUND The primary objective of this study was to determine whether alterations in the pulse oximeter waveform characteristics would track progressive reductions in central blood volume. We also assessed whether changes in the pulse oximeter waveform provide an indication of blood loss in the hemorrhaging patient before changes in standard vital signs. METHODS Pulse oximeter data from fin...
متن کاملMonitoring respiration rate in PACU patients using the plethysmogram from a pulse oximeter
Introduction Post-operative patients with undiagnosed obstructive sleep apnea are at risk of sudden respiratory failure after receiving anesthesia because of repressed respiratory and hemodynamic responses [1] . While all patients have their oxygen saturation automatically monitor in the Post Anesthesia Care Unit (PACU), few have their respiration rate monitored. The goal of our study is to dev...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Respiratory care
دوره 51 7 شماره
صفحات -
تاریخ انتشار 2006