Comparison of bronchodilator responses and deposition patterns of salbutamol inhaled from a pressurised metered dose inhaler, as a dry powder, and as a nebulised solution.
نویسندگان
چکیده
The lung dose and deposition patterns of drug delivered by dry powder inhaler are not known. The effects of inhaling 400 micrograms salbutamol delivered by dry powder inhaler (two 200 micrograms salbutamol Rotacaps), by pressurised metered dose inhaler, and by Acorn nebuliser were studied in nine subjects with chronic stable asthma. Technetium-99m labelled Teflon particles were mixed with micronised salbutamol in the pressurised metered dose inhaler and in the capsules; technetium-99m labelled human serum albumin was mixed with the salbutamol solution for the nebuliser study. The pressurised metered dose inhaler deposited 11.2% (SEM 0.8%) of the dose within the lungs; this was significantly more than the dose deposited by the dry powder inhaler (9.1% (0.6%], but did not differ significantly from the dose delivered by the nebuliser (9.9% (0.7%]. Distribution within the peripheral third of the lung was significantly greater with the nebuliser than with the other two systems; FEV1 improved to a significantly greater extent after inhalation of 400 micrograms salbutamol from the pressurised metered dose inhaler (35.6% from baseline) than from the nebuliser (25.8%) or dry powder inhaler (25.2%). Thus after inhalation of similar doses of salbutamol a larger proportion of drug was deposited within the lungs when it was inhaled from a metered dose inhaler than from a dry powder system; the nebuliser achieved the greatest peripheral deposition. The bronchodilator response seems to depend on the amount of drug within the lungs rather than its pattern of distribution.
منابع مشابه
Comparison of terbutaline and placebo from a pressurised metered dose inhaler and a dry powder inhaler in a subgroup of patients with asthma.
BACKGROUND Reversibility after administration of an inhaled bronchodilator is not always demonstrable in patients with asthma. Bronchodilator aerosol-induced bronchoconstriction has also been reported to occur in some patients. METHODS Fifteen selected patients showing < 10% improvement in forced expiratory volume in one second (FEV1) when tested with four doses of salbutamol (0.1 mg/dose) or...
متن کاملSystematic review of clinical effectiveness of pressurised metered dose inhalers versus other hand held inhaler devices for delivering corticosteroids in asthma.
OBJECTIVE To determine the clinical effectiveness of pressurised metered dose inhalers (with or without spacer) compared with other hand held inhaler devices for the delivery of corticosteroids in stable asthma. DESIGN Systematic review of randomised controlled trials. DATA SOURCES Cochrane Airways Group trials database (Medline, Embase, Cochrane controlled clinical trials register, and han...
متن کاملRacial stereotyping: survey of psychiatrists in the United Kingdom.
responses to salbutamol using Diskhaler versus metered-dose inhaler. Comparison of the bronchodilating efficacies of a novel salbutamol metered dose powder inhaler and a pressurised metered dose aerosol with a spacer. Efficacy of a new non-ozone depleting formulation for salbutamol. Comparison of inhaled ter-butaline administered by either the Turbuhaler dry powder or a metered-dose inhaler wit...
متن کاملImprovement of drug delivery with a breath actuated pressurised aerosol for patients with poor inhaler technique.
BACKGROUND The metered dose inhaler is difficult to use correctly, synchronising actuation with inhalation being the most important problem. A breath actuated pressurised inhaler, designed to help patients with poor inhaler technique, was compared with a conventional metered dose inhaler in terms of aerosol deposition and bronchodilator response. METHODS Radioaerosol deposition and bronchodilat...
متن کاملProtection against methacholine-induced bronchospasm: salbutamol pMDI versus Clickhaler DPI.
Passive dry-powder inhalers (DPIs) have been developed as an alternative to pressurised metered-dose inhalers (pMDIs) to improve aerosol delivery on inhalation and eliminate the need for propellants. However, new DPI formulations of generic drugs must be rigorously compared with conventional pMDI therapy. This randomised, double-blind, double-dummy, placebo-controlled, seven-way crossover study...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Thorax
دوره 45 6 شماره
صفحات -
تاریخ انتشار 1990