Hades, A Radiographic Simulation Code

نویسندگان

  • M. B. Aufderheide
  • D. M. Sone
  • A. E. Schach
چکیده

We describe features of the HADES radiographic simulation code. We begin with a discussion of why it is useful to simulate transmission radiography. The capabilities of HADES are described, followed by an application of HADES to a dynamic experiment recently performed at the Los Alamos Neutron Science Center. We describe quantitative comparisons between experimental data and HADES simulations using a copper step wedge. We conclude with a short discussion of future work planned for HADES.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Hardware Visualization of the Advanced Encryption Standard (AES) Algorithm

Advanced Encryption Standard (AES) was issued as FIPS by NIST as a successor to data encryption standard (DES) algorithms. The applications of the AES are wide including any sensitive data requires cryptographic protection before communication or storage. Thus, many students are interested in learning how the AES is working. One of the inherent limitations of traditional methods for explaining/...

متن کامل

Simulation studies of the HADES first level trigger. PART I: Performance in heavy-ion induced reactions

The first level trigger of the HADES spectrometer is studied for the heavy-ion collision systems Au+Au and Ne+Ne. The trigger efficiency for central events is given in dependence of the imposed charged particle multiplicity condition. The timing properties of the trigger signal are described. The losses due to deadtime are specified. Finally, the first level trigger rate is reported. UCY–PHY–96...

متن کامل

Simulation studies of the HADES first level trigger. PART II: Performance in hadron induced reactions

The HADES first level trigger is studied for the system p+Ni at a beam energy of 2 AGeV. The timing properties of the trigger signal are reported. The efficiency loss due to deadtime is specified. A trigger requirement of a time overlap window with the start detector is described. The trigger rates for different overlap windows are given. UCY–PHY–96/15 1 Corresponding author, e-mail ”schicker@a...

متن کامل

s . in s - de t ] 2 A pr 2 00 4 The HADES Tracking System

The HADES dielectron spectrometer has recently launched its physics program at the heavy ion synchrotron SIS at GSI Darmstadt. The spectroscopy of vector mesons in heavy ion collisions via their dielectron decay channel makes great demands on the HADES tracking system regarding acceptance and spatial resolution. The tracking system is formed out of 24 low-mass, trapezoidal multi-layer drift cha...

متن کامل

Percentage depth dose curves comparison between L - alanine minidosimeters , radiographic film and PENELOPE Monte Carlo simulation for a 60 Co beam

Depth-dose curves for cobalt photon beams were experimentally determined in homogeneous acrylic phantoms and compared to dose distributions calculated by Monte Carlo simulation. The measurements of the depth-dose curves were performed with L-alanine minidosimeters, Kodak X-Omat V radiographic films and with cylindrical ionization chambers. The Co source and the phantom and Lalanine minidosimete...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2000