Application of Maximum Likelihood Principal Components Regression to Fluorescence Emission Spectra
نویسندگان
چکیده
The application of maximum likelihood multivariate calibration methods to the uorescence emission spectra of mixtures of acenaphthylene, naphthalene, and phenanthrene in acetonitrile is described. Maximum likelihood principal components regression (MLPCR) takes into account the measurement error structure in the spectral data in constructing the calibration model. Measurement errors for the uorescence spectra are shown to exhibit both a heteroscedastic and correlated noise structure. MLPCR is compared with principal components regression (PCR) and partial least-squares regression (PLS). The application of MLPCR reduces the prediction errors by about a factor of two over PCR and PLS when a pooled estimate of the measurement error covariance matrix is employed. However, when only the heteroscedascity is incorporated into MLPCR, no improvement in results is observed, indicating the importance of accounting for correlated measurement errors.
منابع مشابه
Combined Unfolded Principal Component Analysis and Artificial Neural Network for Determination of Ibuprofen in Human Serum by Three-Dimensional Excitation–Emission Matrix Fluorescence Spectroscopy
This study describes a simple and rapid approach of monitoring ibuprofen (IBP). Unfolded principal component analysis-artificial neural network (UPCA-ANN) and excitation-emission spectra resulted from spectrofluorimetry method were combined to develop new model in the determination of IBF in human serum samples. Fluorescence landscapes with excitation wavelengths from 235 to 265 nm and emission...
متن کاملCombined Unfolded Principal Component Analysis and Artificial Neural Network for Determination of Ibuprofen in Human Serum by Three-Dimensional Excitation–Emission Matrix Fluorescence Spectroscopy
This study describes a simple and rapid approach of monitoring ibuprofen (IBP). Unfolded principal component analysis-artificial neural network (UPCA-ANN) and excitation-emission spectra resulted from spectrofluorimetry method were combined to develop new model in the determination of IBF in human serum samples. Fluorescence landscapes with excitation wavelengths from 235 to 265 nm and emission...
متن کاملMCR of the quenching of the EEM of fluorescence of Aflatoxins (B1, G1) by Gold nanoparticles
In This research, gold nanoparticles were synthesized and functionalized by the antibody of aflatoxins. The quenching of the fluorescence of excitation emission matrices (EEM) of two type of aflatoxins (B1, G1), provoked by the gold nanoparticles, was studied by principal component analysis (PCA) and multivariate curve resolution with alternating least squares (MCR-ALS). These aflatoxins show q...
متن کاملMCR of the quenching of the EEM of fluorescence of Aflatoxins (B1, G1) by Gold nanoparticles
In This research, gold nanoparticles were synthesized and functionalized by the antibody of aflatoxins. The quenching of the fluorescence of excitation emission matrices (EEM) of two type of aflatoxins (B1, G1), provoked by the gold nanoparticles, was studied by principal component analysis (PCA) and multivariate curve resolution with alternating least squares (MCR-ALS). These aflatoxins show q...
متن کاملA pyroelectric infrared biometric system for real-time walker recognition by use of a maximum likelihood principal components estimation (MLPCE) method.
This paper presents a novel biometric system for real-time walker recognition using a pyroelectric infrared sensor, a Fresnel lens array and signal processing based on the linear regression of sensor signal spectra. In the model training stage, the maximum likelihood principal components estimation (MLPCE) method is utilized to obtain the regression vector for each registered human subject. Rec...
متن کامل