In vitro assessment of equipment and software to assess tidal breathing parameters in infants.
نویسندگان
چکیده
The aim of this in vitro study was to compare the measurement accuracy of two currently available devices for measuring tidal breathing in infants. A mechanical model pump was used to generate flow profiles which simulated those observed in infants. A range of flows was applied simultaneously to two different devices, namely the commercially available SensorMedics 2600 (SM 2600) and more recently developed, custom-made equipment based on the flow-through technique (FTT). Automatically derived values from both devices were compared with one another and with manual calculations of printouts of the same breaths. There were no differences in the raw flow signal obtained from the two devices, nor between values calculated automatically or manually from the FTT. Similarly, the deviations between the FTT and SM 2600 were <3% for tidal volume, respiratory frequency and minute ventilation. However, when comparing either with manually calculated values or those derived automatically from the FTT, there was a systematic and highly significant underestimation of shape-dependent parameters, such as the time to peak tidal expiratory flow as a proportion of tidal expiratory time (tPTEF/tE), derived by the SM 2600. The lower the applied flow, the higher the observed deviations, the underestimation being up to 60% when flows simulating those observed in preterm neonates were applied. These errors appear to result from differences in signal processing such as the algorithms used for breath detection and can only be detected if appropriate nonsinusoidal flow profiles representing those seen in infants are used to evaluate equipment.
منابع مشابه
Tidal breath analysis for infant pulmonary function testing. ERS/ATS Task Force on Standards for Infant Respiratory Function Testing. European Respiratory Society/American Thoracic Society.
The aim of this position paper is to provide recommendations pertaining to software and equipment requirements when analysing tidal breathing measurements in infants. These guidelines cover numerous aspects including terminology and definitions, equipment, data acquisition and analysis, and reporting of results, and highlight areas in which further research is needed before consensus can be rea...
متن کاملMeasuring tidal breathing parameters using a volumetric vest in neonates with and without lung disease.
Lung function measurement is difficult in unsedated infants; tidal breathing parameters are a useful non-invasive surrogate, but even these measurements cause disturbance from applying a facemask. We investigated a novel volumetric vest system (FloRight), which measures volume changes of the respiratory system from changes in the magnetic fields induced by current-carrying coils around the enti...
متن کاملAssessment of tidal breathing parameters in infants with cystic fibrosis.
Simple methods are needed to assess lung function in infants with cystic fibrosis (CF). This study determined the relationship between simple measurements obtained from tidal breathing with those from more complicated forced expiratory manoeuvres. Healthy infants and infants with CF were recruited from two maternity units and five specialist CF hospitals, respectively. Respiratory rate, tidal v...
متن کاملElectromagnetic inductance plethysmography is well suited to measure tidal breathing in infants
Reliable, accurate and noninvasive methods for measuring lung function in infants are desirable. Electromagnetic inductance plethysmography has been used to perform infant spirometry and VoluSense Pediatrics (VSP) (VoluSense, Bergen, Norway) represents an updated version of this technique. We aimed to examine its accuracy compared to a validated system measuring airflow via a facemask using an ...
متن کاملDifferences in tidal breathing between infants with chronic lung diseases and healthy controls
BACKGROUND The diagnostic value of tidal breathing (TB) measurements in infants is controversially discussed. The aim of this study was to investigate to what extent the breathing pattern of sleeping infants with chronic lung diseases (CLD) differ from healthy controls with the same postconceptional age and to assess the predictive value of TB parameters. METHODS In the age of 36-42 postconce...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The European respiratory journal
دوره 17 1 شماره
صفحات -
تاریخ انتشار 2001