The effect of eating on thallium myocardial imaging.
نویسندگان
چکیده
To determine if eating between initial and delayed thallium images alters the appearance of the delayed thallium scan, a prospective study was performed; 184 subjects sent for routine thallium imaging were randomized into two groups, those who ate a meal high in carbohydrates between initial and delayed thallium myocardial images (n = 106), and those who fasted (n = 78). The 201Tl images were interpreted in blinded fashion for global myocardial and pulmonary clearance of 201Tl myocardial defects. The eating group had a significantly lower incidence of transient myocardial defects compared to the noneating group (7 percent vs 18 percent, respectively; p less than 0.05). The time between initial and delayed images and the incidence of exercise-induced ischemic ST-segment depression or pathologic Q waves on the electrocardiogram were not significantly different between the two groups. These data suggest that eating a high-carbohydrate meal between initial and delayed 201Tl images causes increased 201Tl myocardial clearance rates and may alter 201Tl myocardial redistribution over time.
منابع مشابه
Serial Myocardial Imaging after a Single Dose of Thallium-201
Although thallium-201 exercise scintigraphy has been established for the detection of myocardial ischemia and viability, little is known regarding the myocardial thallium-201 kinetics during angioplasty. Herein, we report a 77-year old man with angina pectoris, in whom serial myocardial imaging after a single dose of thallium-201 was helpful in identifying not only the culprit lesion and myocar...
متن کاملMyocardial damage of the entire ventricular region in a patient with acute myocardial infarction
Technetium-99m-pyrophosphate (99mTc-PYP) has been used, in combination with thallium-201, to estimate the site and extent of myocardial infarcts. We report a case of acute myocardial infarction with severe coronary disease in which the distribution of 99mTc-PYP was extensive. A 78-year-old man presented with dyspnea, and a diagnosis of non-ST-segment elevation acute myocar...
متن کاملEnergy window setting for optimum Tl-201 cardiac imaging [Persian]
Introduction: Poor sensitivity and poor signal to noise ratio because of low injected thallium dose and presence of scattered photons are the main problems in using thallium in scintigraphic imaging of the heart. Scattered photons are the main cause of degrading the contrast and resolution in SPECT imaging that result in error in quantification. Thallium decay is ve...
متن کاملThe first performance of myocardial perfusion scintigraphy, post intravenous Dipyridamole injection
SUMMARY Dipyridamolc-Thallium imaging is a relatively safe and accurate method to evaluate myocardial perfusion in patients who arc unable to exercise to a maximal exertion (5,6,8,9). A 51year-old woman was admitted to Taleghani hospital with clinical symptoms and signs of coronary artery disease. Intravenous dipyridamote-Thallium scan was performed in this case. In multiple views obtained f...
متن کاملThe effect of pomegranate juice, lemon juice and secanjabin in reducing infra-cardiac activity of 99mTc-MIBI during myocardial perfusion imaging in comparison with fatty food
Introduction: Eating fatty food is a common technique for decreasing extra cardiac activity, but sometimes patients refuse to eat fatty foods due to various reasons during myocardial perfusion imaging. The aim of this study is to introduce an alternative method for patients who are not able to use fatty foods to accelerate the transit of radiotracer from the liver. <stron...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Chest
دوره 89 2 شماره
صفحات -
تاریخ انتشار 1986