Computed tomography evaluation of rotary systems on the root canal transportation and centering ability.
نویسندگان
چکیده
The endodontic preparation of curved and narrow root canals is challenging, with a tendency for the prepared canal to deviate away from its natural axis. The aim of this study was to evaluate, by cone-beam computed tomography, the transportation and centering ability of curved mesiobuccal canals in maxillary molars after biomechanical preparation with different nickel-titanium (NiTi) rotary systems. Forty teeth with angles of curvature ranging from 20° to 40° and radii between 5.0 mm and 10.0 mm were selected and assigned into four groups (n = 10), according to the biomechanical preparative system used: Hero 642 (HR), Liberator (LB), ProTaper (PT), and Twisted File (TF). The specimens were inserted into an acrylic device and scanned with computed tomography prior to, and following, instrumentation at 3, 6 and 9 mm from the root apex. The canal degree of transportation and centering ability were calculated and analyzed using one-way ANOVA and Tukey's tests (α = 0.05). The results demonstrated no significant difference (p > 0.05) in shaping ability among the rotary systems. The mean canal transportation was: -0.049 ± 0.083 mm (HR); -0.004 ± 0.044 mm (LB); -0.003 ± 0.064 mm (PT); -0.021 ± 0.064 mm (TF). The mean canal centering ability was: -0.093 ± 0.147 mm (HR); -0.001 ± 0.100 mm (LB); -0.002 ± 0.134 mm (PT); -0.033 ± 0.133 mm (TF). Also, there was no significant difference among the root segments (p > 0.05). It was concluded that the Hero 642, Liberator, ProTaper, and Twisted File rotary systems could be safely used in curved canal instrumentation, resulting in satisfactory preservation of the original canal shape.
منابع مشابه
Comparison of Canal Transportation and Centering Ability of Wave One and SafeSider in Curved Root Canals Using Cone-Beam Computed Tomography
Background and Aim: Maintaining the original central canal path during cleaning and shaping of the root canal system plays an important role in the success of endodontic treatment. This study sought to compare canal transportation and centering ability of WaveOne and SafeSider rotary files using cone-beam computed tomography (CBCT). Materials and Methods: This in-vitro, experimental study was ...
متن کاملEvaluation of Canal Transportation and Centering Ability of Safesider and K-Flexofile: Using Cone-beam Computed Tomography
Abstract Background and aim: Maintaining the original geometry of canal is an important parameter in successful root canal treatment. The aim of this original study was evaluation of apical root canal transportation and centering ability of SafeSider and K-Flexofile using cone beam computed tomography. Materials and Methods: Mesiobuccal root canals of maxillary first molars, with 20-40° curvatu...
متن کاملComparison of transportation and centering ability using RECIPROC and iRace: A cone-beam computed tomography study
BACKGROUND AND AIM: Root canal treatment, especially in curved and constricted root canals, can be very difficult and time consuming. Several investigations have compared the reciprocating and full sequence motions in terms of shaping ability. The purpose of the present study was to compare the root canal transportation and centering ability of RECIPROC and iRace using cone-beam computed tomogr...
متن کاملEvaluation of Root Canal Transportation using Bio Race and K -Flexo file instruments: using cone-Bean Computed
Background & Aim: Deviation from the original shape of the canal leads to poor filling and lack of proper canal seal and consequently to the failure of root treatment The aim of this experimental study was to determine the extent of apical transportation after instrumentation with hand K-Flexofile and BioRace rotary instruments by cone-beam computed tomography (CBCT). Material and Methods: In t...
متن کاملAn in-vitro Evaluation of canal transportation and centering ability of two rotary Nickel Titanium systems (Twisted Files and Hyflex files) with conventional stainless Steel hand K-flexofiles by using Spiral Computed Tomography.
BACKGROUND The purpose of this in-vitro study was to compare canal transportation and centering ability of Twisted and Hyflex Rotary Files with stainless steel hand k-flexofiles by using Spiral Computed Tomography. MATERIALS & METHODS A total of 90 freshly extracted human mandibular single rooted Premolar teeth were selected. The crowns were flattened with steel disks and a final dimension of...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Brazilian oral research
دوره 29 شماره
صفحات -
تاریخ انتشار 2015